m+Medelevator.RU
← Поиск публикаций
The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons · 2015

Use of a spinal cage for creating stable constructs in ankle and subtalar fusion.

Clinical StudyСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Palmanovich Ezequiel, Brin Yaron S, Ben David Dror, Massarwe Sabri, Stern Abraham, Nyska Meir, Hetsroni Iftach

Аннотация

In complicated foot surgery with reconstruction of the hindfoot, a gap will sometimes be present between the bones that must be filled and stabilized. Bone grafting with structural bone graft is 1 alternative; however, it can collapse and must be stabilized with screws or a nail. A locking intramedullary nail can be used but could lead to nonunion owing to distraction. Newer nails include a compression device but that can result in shortening. We developed a technique that includes distraction of the fusion area with a spinal cage and then compression of the construct by inserting a compression screw through the cage. We present our experience with this technique.We reviewed the data from 7 patients who had undergone surgery using this technique. The technique included distraction of the fusion area and insertion of a titanium cylindrical spinal cage filled with autologous cancellous bone graft. A cannulated compression screw was then inserted through the cage, creating compression of the fusion area against the cage and achieving stabilization of the fusion area. Postoperatively, a non-weightbearing cast was applied for 3 months, followed by a full weightbearing cast until radiographic fusion was apparent. Complete radiographic union was observed in all 7 patients within 6 to 12 months postoperatively. At the latest follow-up visit, the mean American Orthopaedic Foot and Ankle Society scale score was 54 ± 16 (range 30 to 71) points. The use of a cylindrical titanium cage with a local bone graft and stabilization by distraction and compression provided a stable construct, avoided shortening, and led to good fusion. In addition, donor site complications and unpredictable strength loss and lysis of bone allograft were avoided.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты