MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/chir.22626

Медицинская библиотека · Chirality · 2016

Simple Isocratic HPLC Method for Determination of Enantiomeric Impurity in Besifloxacin Hydrochloride.

Kumar G Pradeep, Srivastava Vishal, Khandelwal Kiran, Kumar Rajesh, Hiriyanna S G, Kumar Ajay, Kumar Pramod

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Besifloxacin is a unique chiral broad-spectrum flouroquinolone used in the treatment of bacterial conjunctivitis. R-form of besifloxacin hydrochloride shows higher antibacterial activity as compared to the S-isomer. Therefore, it is necessary to establish chiral purity. To establish chiral purity a high-performance liquid chromatography (HPLC) method for determination of R-besifloxacin and S-besifloxacin (BES impurity A) was developed and validated for in-process quality control and stability studies. The analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD), and lower limit of quantification (LOQ) were determined according to International Council for Harmonization ICH Q2(R1) guidelines. HPLC separation was achieved on Chiralpak AD-H (250 x 4.6 mm, 5 μm) column using n-heptane: ethanol: ethylenediamine: acetic acid (800:200:0.5:0.5) (v/v/v/v) as the mobile phase in an isocratic elution. The eluents were monitored by UV/Visible detector at 290 nm. The resolution between S-isomer and besifloxacin hydrochloride was more than 2.0. Based on a signal-to-noise ratio of 3 and 10 the LOD of besifloxacin was 0.30 μg/mL, while the LOQ was 0.90 μg/mL. The calibration curves were linear in the range of 0.9-7.5 μg/mL. Precision of the method was established within the acceptable range. The method was suitable for the quality control enantiomeric impurity in besifloxacin hydrochloride. Chirality 28:628-632, 2016. © 2016 Wiley Periodicals, Inc.

Для цитирования: Kumar G Pradeep, Srivastava Vishal, Khandelwal Kiran, Kumar Rajesh, Hiriyanna S G, Kumar Ajay, Kumar Pramod. Simple Isocratic HPLC Method for Determination of Enantiomeric Impurity in Besifloxacin Hydrochloride.. Chirality. 2016. DOI: 10.1002/chir.22626.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.