MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0002-9149(88)91077-6

Медицинская библиотека · The American journal of cardiology · 1988

Doppler ultrasound evaluation of valvar pulmonary stenosis from multiple transducer positions in children requiring pulmonary valvuloplasty.

Frantz E G, Silverman N H

СтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

The modified Bernoulli equation has been used to determine the peak pressure difference across stenotic pulmonary valves. The direction of the poststenotic jet may be eccentric in relation to the axis of the pulmonary artery. Consequently, the maximal velocity obtained from the parasternal transducer position may inaccurately estimate peak pressure difference. Thus, Doppler-derived estimates of pressure difference from the parasternal, subcostal, apical, and suprasternal notch transducer positions were compared with peak-to-peak pulmonary artery to right ventricle catheter withdrawal pressure differences in 24 patients admitted for pulmonary valvuloplasty. Suprasternal, subcostal or apical transducer positions produced higher maximal velocities than the parasternal transducer position in 12 of 24 patients when the studies were performed before cardiac catheterization and in 8 of 12 patients when performed during cardiac catheterization. The Doppler-derived estimates using the highest maximal velocity predicted catheterization pressure difference accurately when the measurements were not performed simultaneously (y = 1.05x - 3.3, r = 0.86, standard error of the estimate +/- 18.7 mm Hg) and the correlation was closer when the measurements were performed simultaneously (y = 1.09x - 2.7, r = 0.97, standard error of the estimate +/- 9.4 mm Hg). The transducer position that yielded the highest maximal velocity in an individual patient was the same before and after valvuloplasty. In all groups, the correlation with pressure at cardiac catheterization was improved by using the highest maximal velocity rather than the parasternal maximal velocity.

Для цитирования: Frantz E G, Silverman N H. Doppler ultrasound evaluation of valvar pulmonary stenosis from multiple transducer positions in children requiring pulmonary valvuloplasty.. The American journal of cardiology. 1988. DOI: 10.1016/0002-9149(88)91077-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.