Broader corneal characterization with PulseESPI applied to elasticity measurements.
Аннотация
PURPOSE: A novel application of pulsed electronic speckle pattern interferometry (PulseESPI) techniques in important corneal elasticity measurements is presented in this pilot study. For laser-ablative procedures like laser-assisted in situ keratomileusis, it has been found that elastic properties of the cornea have a role in the outcome of corneal refractive surgery, while for optimal ablative laser power calculations this measurement method may possibly be helpful. It may also help in earlier diagnosis of degenerative corneal disorders such as keratoconus.
METHODS
The approach of this study is to observe dynamic behavior of cornea against stresses as mapped with PulseESPI. For this purpose, strain was induced to the cornea using a fine rod with a mechanical vibrator.
RESULTS
It was found that cornea has a response pattern to the dynamic stressing. Its surface exhibits a resonance frequency which can be measured with PulseESPI. This information of resonance frequency can be characteristic to the cornea.
CONCLUSIONS
PulseESPI may help in important corneal elasticity measurements used for complication-free optimized ophthalmic surgery. It seems to be a promising method to conduct stress-related investigations on biological samples. To our knowledge, this is the first time that PulseESPI has been used for such ophthalmic measurements.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.