Zhou Xiao-Biao, Chen Xin, Wang Zhan, Chen Ding-Qiang, Li Rui, Li Li, Xu Lin-Xi, Chen Zhi-Huang, Song Man, Huang Jian, Zhuang Jia-Wei, Cheng Gang-Yi, Xu Qing-Xin, Zhu Zhuang-Hui, Shan Zhong-Gui
Аннотация
OBJECTIVE: To analyze the outcome of 147 cases of type B aortic dissection with thoracic endovascular aortic repair (TEVAR).
METHODS: We systematically reviewed 147 patients of type B aortic dissection with stent graft deployment in zone 2 or zone 3 by TEVAR from January 2012 to December 2022. These patients were observed by computed tomography angiography after the first and third months and annually thereafter during follow-up. Statistical analysis was performed by SPSS.16.
RESULTS: The stent graft of 107 patients was deployed in zone 3, and the stent graft of 40 patients was deployed in zone 2. Severe dissection and surgery-related complications after TEVAR occurred in 19 patients, with complications arising more frequently in zone 2 than in zone 3 (12/40 vs. 7/107, P < 0.005). Endoleak was detected in 10 (6.8%, 10/147) cases, which included 6 cases of endoleak in zone 2, exceeding the 4 cases of endoleak in zone 3 (6/40 vs. 4/107, P < 0.05). Twelve (8.16%, 12/147) cases underwent re-intervention, and the 8 patients who underwent re-intervention in zone 2 exceeded the 4 patients who underwent re-intervention in zone 3 (8/40 vs. 4/107, P < 0.05). One case of subclavian steal in zone 2 (0.68%, 1/147). Two (1.36%, 2/147) cases died after TEVAR. The 1-year, 3-year, and 5-year overall survival rates were 99.3%, 98.6%, and 98.6%, respectively. The re-intervention rates were 5.4%, 7.5%, and 8.2%, respectively. The re-intervention rates in zone 2 were 15%, 20%, and 20%, respectively. The re-intervention rates in zone 3 were 1.9%, 2.8%, and 3.7%, respectively.
CONCLUSION: TEVAR is the major treatment to use if the stent graft can be deployed in zone 3. However, with the higher rate of complications and re-intervention after TEVAR, for patients whose stent graft can only be deployed in zone 2, it is not recommended that TEVAR be chosen as the preferred treatment.
METHODS: We systematically reviewed 147 patients of type B aortic dissection with stent graft deployment in zone 2 or zone 3 by TEVAR from January 2012 to December 2022. These patients were observed by computed tomography angiography after the first and third months and annually thereafter during follow-up. Statistical analysis was performed by SPSS.16.
RESULTS: The stent graft of 107 patients was deployed in zone 3, and the stent graft of 40 patients was deployed in zone 2. Severe dissection and surgery-related complications after TEVAR occurred in 19 patients, with complications arising more frequently in zone 2 than in zone 3 (12/40 vs. 7/107, P < 0.005). Endoleak was detected in 10 (6.8%, 10/147) cases, which included 6 cases of endoleak in zone 2, exceeding the 4 cases of endoleak in zone 3 (6/40 vs. 4/107, P < 0.05). Twelve (8.16%, 12/147) cases underwent re-intervention, and the 8 patients who underwent re-intervention in zone 2 exceeded the 4 patients who underwent re-intervention in zone 3 (8/40 vs. 4/107, P < 0.05). One case of subclavian steal in zone 2 (0.68%, 1/147). Two (1.36%, 2/147) cases died after TEVAR. The 1-year, 3-year, and 5-year overall survival rates were 99.3%, 98.6%, and 98.6%, respectively. The re-intervention rates were 5.4%, 7.5%, and 8.2%, respectively. The re-intervention rates in zone 2 were 15%, 20%, and 20%, respectively. The re-intervention rates in zone 3 were 1.9%, 2.8%, and 3.7%, respectively.
CONCLUSION: TEVAR is the major treatment to use if the stent graft can be deployed in zone 3. However, with the higher rate of complications and re-intervention after TEVAR, for patients whose stent graft can only be deployed in zone 2, it is not recommended that TEVAR be chosen as the preferred treatment.
Предметные рубрики MeSH
HumansAortic DissectionEndovascular ProceduresMaleStentsBlood Vessel Prosthesis ImplantationFemaleMiddle AgedAortic Aneurysm, ThoracicTreatment OutcomeBlood Vessel ProsthesisRetrospective StudiesTime FactorsAgedRisk FactorsEndoleakAdultRisk AssessmentPostoperative ComplicationsEndovascular Aneurysm Repair