Comparing thermal discomfort with skin temperature response of lower-limb prosthesis users during exercise.

Diment Laura E, Thompson Mark S, Bergmann Jeroen H M

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Thermal discomfort is prevalent among prosthesis users. This observational study of thirty unilateral lower-limb prosthesis users compared their skin temperatures and the thermal discomfort experienced during exercise between their residual and contralateral limbs.

METHODS

Participants performed a 2-minute interval cycling exercise test. Skin temperature was measured at matched locations on each leg during the 1-minute rest intervals. Average rate-of-change in skin temperature was compared between legs using a repeated measures analysis of variance. Participants rated thermal discomfort on each leg before and after exercise, and a Wilcoxon signed-rank test was used to compare legs. Ordinal regression evaluated the relationship between the rate-of-change in temperature on the residual limb and the perceived thermal discomfort.

FINDINGS: After exercise, thermal discomfort ranked higher on the amputated side (P = 0.007). On average, both legs cooled during exercise (P = 0.002), but the difference between legs was not significant. The rate-of change in skin temperature on the residual limb during exercise did not relate to the thermal discomfort experienced (odds ratio of 0.357).

INTERPRETATION: These findings indicate that in this patient population, skin temperature does not explain the thermal discomfort experienced, and subjective thermal discomfort is inadequate for detecting thermoregulatory issues, with potential implications for long-term tissue health.

Для цитирования: Diment Laura E, Thompson Mark S, Bergmann Jeroen H M. Comparing thermal discomfort with skin temperature response of lower-limb prosthesis users during exercise.. Clinical biomechanics (Bristol, Avon). 2019. DOI: 10.1016/j.clinbiomech.2019.07.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.