m+Medelevator.RU
← Поиск публикаций
Journal of thrombosis and thrombolysis · 2022

Comparison of biodegradable and newer generation durable polymer drug-eluting stents with short-term dual antiplatelet therapy: a systematic review and Bayesian network meta-analysis of randomized trials comprising of 43,875 patients.

СтатьяСистематический обзорNetwork Meta-AnalysisНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chong Bryan, Goh Rachel Sze Jen, Kong Gwyneth, Sim Faith Ruo En, Ng Chen Han, Teo Xin Yi Vanessa, Quek Jing Xuan, Lim Oliver, Chin Yip Han, Chan Siew-Pang, Chan Mark Y, Tan Huay-Cheem, Chew Nicholas W S, Loh Poay Huan

Аннотация

Newer generation durable polymer drug-eluting stents (DP-DES) and biodegradable polymer DES (BP-DES) have similar efficacy with dual-antiplatelet therapy (DAPT) duration of > 6 months. However, this difference in outcomes have not been well studied in shorter DAPT regime. This study compares the safety and efficacy profiles of DP-DES and BP-DES based on short-term (1-3 months), intermediate-term (4-6 months) and standard DAPT (6-12 months) durations. A search was conducted on Embase and Medline for Randomized Controlled Trials (RCTs) comparing stent types, and DAPT durations. Primary endpoints include cardiac death, myocardial infarction (MI), definite stent thrombosis, stroke, target vessel revascularization (TVR) and major bleeding. Network analysis was conducted to summarize the evidence. A total of 15 RCTs involving 43,875 patients were included. DP-DES was associated with significantly lower major bleeding rates compared to BP-DES (RR 0.44, Crl 0.22-0.83) in short-term DAPT. Among DP-DES patients, short-term DAPT was associated with lower major bleeding risk compared to standard DAPT (RR 0.47, CrI 0.32-0.69). This favorable bleeding profile with short DAPT was not found in BP-DES patients. Cardiac death, MI, definite stent thrombosis, stroke and TVR rates were similar across the various DAPT durations and stent types. Our preliminary findings demonstrated comparable efficacy and safety outcomes between BP-DES and newer generation BP-DES across various DAPT durations. In patients requiring short DAPT, DP-DES had more favourable major bleeding profile compared to BP-DES, without compromising anti-thrombotic efficacy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты