DOI 10.1177/112067210601600116

Медицинская библиотека · European journal of ophthalmology · 2006

Long-term clinical results of selective laser trabeculoplasty in the treatment of primary open angle glaucoma.

Weinand F S, Althen F

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the long-term efficacy of selective laser trabeculoplasty (SLT) in primary open-angle glaucoma, the authors performed a non-randomized, prospective, non-comparative clinical case series.

METHODS

Fifty-two eyes of 52 patients (19 male, 33 female) with primary open angle glaucoma were treated with SLT. Patients were treated with the Coherent Selecta 7000 (Coherent, Palo Alto, CA, USA) frequency-doubled q-switched Nd:YAG laser (532 nm). A total of approximately 50 non-overlapping spots were placed over 180 degrees of the trabecular meshwork at energy levels ranging from 0.6 to 1.4 mJ per pulse. After surgery, patients were maintained with the drug regimen identical to that before treatment.

RESULTS

After 1 year the average reduction in intraocular pressure (IOP) from the baseline was 24.3% (6.0 mmHg), after 2 years 27.8% (6.12 mmHg), after 3 years 24.5% (5.53 mmHg), and after 4 years 29.3% (6.33 mmHg). A Kaplan-Meier survival analysis revealed a 1-year success rate of 60%, a 2-year success rate of 53%, a 3-year success rate of 44%, and a 4-year success rate of 44%.

CONCLUSIONS

Despite a declining success rate, SLT is an effective method to lower IOP over an extended period of time.

Для цитирования: Weinand F S, Althen F. Long-term clinical results of selective laser trabeculoplasty in the treatment of primary open angle glaucoma.. European journal of ophthalmology. 2006. DOI: 10.1177/112067210601600116.