MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rgmxen.2023.08.009

Медицинская библиотека · Revista de gastroenterologia de Mexico (English) · 2024

A new formula proposal for placing pH-impedance catheters in pediatric patients.

Sempértegui-Cárdenas P X, Toro-Monjaraz E M, Zárate-Mondragón F E, Ignorosa-Arellano K, Cadena-León J F, Cervantes-Bustamante R, Montijo-Barrios E, Ramírez-Mayans J A

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Esophageal pH-impedance monitoring is a tool for diagnosing gastroesophageal reflux in children. The position of the pH catheter is essential for a reliable reading and the current formulas for calculating catheter insertion length are not completely accurate. The aim of the present study was to develop a new formula for adequate insertion of the pH catheter.

MATERIAL AND

METHODS

A cross-sectional study was conducted on children that underwent pH-impedance monitoring and later radiographic control, to calculate the correct catheter insertion length. The documented variables were age, sex, weight, height, naris to tragus distance, tragus to sternal notch distance, sternal notch to xiphoid process distance, and initial insertion length determined by the Strobel and height interval formulas. A multivariate regression analysis was carried out to predict the final insertion length. Regression ANOVA and Pearson's adjusted R-squared tests were performed.

RESULTS

Forty-five pH-impedance studies were carried out, 53% of which were in males. The age and weight variables were not normally distributed. In the initial regression model, the variables that did not significantly correlate with the final insertion length were: sex (P 0.124), length determined by the Strobel or height interval formulas (P 0.078), naris to tragus distance (P 0.905), and tragus to sternal notch distance (P 0.404). The final equation: 5.6 + (height in cm * 0.12) + (sternal notch to xiphoid process distance * 0.57) produced an R2 of 0.93 (P 0.000).

CONCLUSIONS

This formula can be considered a valid option for placement of the pH-impedance monitoring catheter in pediatrics.

Для цитирования: Sempértegui-Cárdenas P X, Toro-Monjaraz E M, Zárate-Mondragón F E, Ignorosa-Arellano K, Cadena-León J F, Cervantes-Bustamante R, Montijo-Barrios E, Ramírez-Mayans J A. A new formula proposal for placing pH-impedance catheters in pediatric patients.. Revista de gastroenterologia de Mexico (English). 2024. DOI: 10.1016/j.rgmxen.2023.08.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.