Agitated saline bubble-enhanced ultrasound for the positioning of cuffed, tunneled dialysis catheters in patients with end-stage renal disease.

Passos Rogerio da Hora, Ribeiro Michel, da Conceição Luis Filipe Miranda Rebelo, Ramos Joao Gabriel Rosa, Ribeiro Juliana Caldas, Batista Paulo Benigno Pena, Dutra Margarida Maria Dantas, Rouby Jean Jacques

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

In patients with end-stage renal disease, the use of cuffed, tunneled dialysis catheters for hemodialysis has become integral to treatment plans. Fluoroscopy is a widely accepted method for the insertion and positioning of cuffed dialysis catheters, because it is easy to use, accurate and reliable, and has a relatively low incidence of complications. The purpose of our study was to evaluate the feasibility of tunneled hemodialysis catheter placement without the use of fluoroscopy but with a dynamic ultrasound-imaging-based guided technique.

METHODS

From January 2015 to December 2017, we performed an observational prospective cohort study of 56 patients with end-stage renal disease who required tunneled dialysis catheter placement.

RESULTS

The overall success rate for ultrasound-guided central access was 100%, with a mean number of 1.16 (±0.4) attempts per patient. There were no incidences of guide wire coiling/kinking, carotid puncture, pneumothorax, or catheter malfunction. Catheter flow during dialysis was 286 (±38) mL/min. The total number of catheter days was 7451, with a mean of 133 days and a range of 46-322 days. Life table analysis revealed primary patency rates of 100%, 96%, and 53% at 30, 60, and 120 days, respectively.

CONCLUSION

Dynamic ultrasound-based visualization of microbubbles in the right atrium is a highly accurate method to detect percutaneous implantation of large-lumen, tunneled, central venous catheters without the need for fluoroscopic guidance technology. Future research should further develop and confirm these initial findings.

Для цитирования: Passos Rogerio da Hora, Ribeiro Michel, da Conceição Luis Filipe Miranda Rebelo, Ramos Joao Gabriel Rosa, Ribeiro Juliana Caldas, Batista Paulo Benigno Pena, Dutra Margarida Maria Dantas, Rouby Jean Jacques. Agitated saline bubble-enhanced ultrasound for the positioning of cuffed, tunneled dialysis catheters in patients with end-stage renal disease.. The journal of vascular access. 2018. DOI: 10.1177/1129729818806121.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.