MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4321/s0365-66912007001200006

Медицинская библиотека · Archivos de la Sociedad Espanola de Oftalmologia · 2007

[Contact lens fitting in 133 eyes with irregular astigmatism].

Galindo-Ferreiro A, Galindo-Alonso J, Sánchez-Tocino H, Palencia-Ercilla J

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To study the adaptation of contact lens in a sample of 133 eyes with irregular astigmatism.

METHODS

A retrospective study was made in 133 eyes with irregular astigmatism. The selection criterion was to obtain a sample population with irregular astigmatism that was unlikely to be corrected with spectacles or conventional contact lens. A complete ophthalmologic exploration which included a topography with the Eye-Sys 2000 corneal topographer was made was made. The variables analyzed in the study were: refraction, visual acuity before and after the correction, cause of the astigmatism and contact lens used.

RESULTS

An equal number of women and men were enrolled in the study. The right eye was studied in 52% of cases, and the left eye in 46%. Both eyes were affected in 67% of the subjects. The reason for the astigmatism was keratoconus in 110 eyes (78.2%), and there were 4 corneal injuries, 9 ocular infections, and 6 idiopathic astigmatisms. Among the contact lens used in the study: in 103 eyes a hybrid lens (Softperm) was adapted, in 20 eyes a piggy-back system, in 5 eyes a thick hydrophilic lens (Queratosoft), in 4 eyes a hydrophilic contact lens and in 3 cases a rigid gas permeable contact lens. The average visual acuity before the adaptation was 0.28 (SD 0.24) (range 0.1-0.8). After the use of the lens the average visual acuity was 0.81 (SD 0.23) (range 0.1-1). Statistically significant differences between the visual acuity before and after treatment were found, with an improvement of 0.53 (SD 0.28) obtained.

CONCLUSION

Only with experience using a large variety of non-conventional contact lens can a specialist contact lens ophthalmologist achieve a good result.

Для цитирования: Galindo-Ferreiro A, Galindo-Alonso J, Sánchez-Tocino H, Palencia-Ercilla J. [Contact lens fitting in 133 eyes with irregular astigmatism].. Archivos de la Sociedad Espanola de Oftalmologia. 2007. DOI: 10.4321/s0365-66912007001200006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.