Assessment of soft and hard tissue dimensions following different treatment approaches of ligature-induced peri-implantitis defects.

Ramanauskaite Ausra, Obreja Karina, Sader Robert, Becker Jürgen, Schwarz Frank

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate peri-implant tissue dimensions following nonsurgical (NS) and surgical therapy (S) employing different decontamination protocols of advanced ligature-induced peri-implantitis in dogs.

MATERIAL &

METHODS

Peri-implantitis defects (n = 5 dogs, n = 30 implants) were randomly and equally allocated in a split-mouth design to NS or S treatment using either an Er:YAG laser (ERL), an ultrasonic device (VUS), or plastic curettes + local application of metronidazole gel (PCM), respectively. Horizontal bone thickness (hBT) and soft tissue thickness (hMT) were measured at different reference points: (v0) at the marginal portion of the peri-implant mucosa (PM); (v1) at 50% of the distance from PM to bone crest (BC); (v2) at the BC; (v3) at the most coronal extension of the bone-to-implant contact. Vertical peri-implant tissue height was calculated from PM to BC.

RESULTS

All of the treatment groups showed a gradual hMT increase from v0 to the v2 reference point, followed by a reduction from v2 to the v3 region. The S-VUS subgroup tended to be associated with higher hMT values at the v0 region than the NS-VUS subgroup (0.44 mm versus 0.31 mm). PM-BC distance varied from 2.22 to 2.83 mm in the NS group, and from 2.07 to 2.38 in the S group.

CONCLUSION

Vertical and horizontal peri-implant tissue dimensions were similar in different treatment groups.

Для цитирования: Ramanauskaite Ausra, Obreja Karina, Sader Robert, Becker Jürgen, Schwarz Frank. Assessment of soft and hard tissue dimensions following different treatment approaches of ligature-induced peri-implantitis defects.. Clinical oral implants research. 2021. DOI: 10.1111/clr.13709.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.