MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjophthalmol-2016-309402

Медицинская библиотека · The British journal of ophthalmology · 2016

Study of Optimal Perimetric Testing In Children (OPTIC): development and feasibility of the kinetic perimetry reliability measure (KPRM).

Patel Dipesh E, Viswanathan Ananth C, Garway-Heath David, Cumberland Phillippa M, Walters Bronwen C, Russell-Eggitt Isabelle, Cortina-Borja Mario, Rahi Jugnoo S, OPTIC Study Group

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Interpretation of perimetric findings, particularly in children, relies on accurate assessment of test reliability, yet no objective measures of reliability exist for kinetic perimetry. We developed the kinetic perimetry reliability measure (KPRM), a quantitative measure of perimetric test reproducibility/reliability and report here its feasibility and association with subjective assessment of reliability.

METHODS

Children aged 5-15 years, without an ophthalmic condition that affects the visual field, were recruited from Moorfields Eye Hospital and underwent Goldmann perimetry as part of a wider research programme on perimetry in children. Subjects were tested with two isopters and the blind spot was plotted, followed by a KPRM. Test reliability was also scored qualitatively using our examiner-based assessment of reliability (EBAR) scoring system, which standardises the conventional clinical approach to assessing test quality. The relationship between KPRM and EBAR was examined to explore the use of KPRM in assessing reliability of kinetic fields.

RESULTS

A total of 103 children (median age 8.9 years; IQR: 7.1 to 11.8 years) underwent Goldmann perimetry with KPRM and EBAR scoring. A KPRM was achieved by all children. KPRM values increased with reducing test quality (Kruskal-Wallis, p=0.005), indicating greater test-retest variability, and reduced with age (linear regression, p=0.015). One of 103 children (0.97%) demonstrated discordance between EBAR and KPRM.

CONCLUSION

KPRM and EBAR are distinct but complementary approaches. Though scores show excellent agreement, KPRM is able to quantify within-test variability, providing data not captured by subjective assessment. Thus, we suggest combining KPRM with EBAR to aid interpretation of kinetic perimetry test reliability in children.

Для цитирования: Patel Dipesh E, Viswanathan Ananth C, Garway-Heath David, Cumberland Phillippa M, Walters Bronwen C, Russell-Eggitt Isabelle, Cortina-Borja Mario, Rahi Jugnoo S, OPTIC Study Group. Study of Optimal Perimetric Testing In Children (OPTIC): development and feasibility of the kinetic perimetry reliability measure (KPRM).. The British journal of ophthalmology. 2016. DOI: 10.1136/bjophthalmol-2016-309402.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.