OBJECTIVE

The goal of this study was to compare the efficacy of midazolam/meperidine (M/M) vs midazolam/hydromorphone (M/H) for enteral moderate sedation along with inhalational sedation in pediatric dental patients.

METHODS

This retrospective chart review analyzed the charts of pediatric patients who received dental treatment under enteral moderate sedation with either M/M or M/H in combination with inhalational sedation (nitrous oxide/oxygen) at El Rio Community Health Centers (affiliated with NYU Langone) in Tucson, Arizona, from July 2014 to December 2020. Included subjects were between 2 and 5 years of age, less than 20 kg, and otherwise healthy. In addition to demographic and drug-dosing data, treatment completion, sedation level, behavioral score, overall effectiveness, and sedation duration data were collected and analyzed from each patient's chart.

RESULTS

No statistically significant differences were observed when comparing the 2 drug regimens in treatment completion (P = .89), sedation level (P = .74), and overall effectiveness (P = .70). There was a statistically significant difference in behavior scoring, with the M/H group demonstrating higher scores (P = .04) than the M/M group.

CONCLUSION

The combination of midazolam and hydromorphone may provide an effective alternative to midazolam and meperidine when used with inhalational sedation (nitrous oxide/oxygen) for the moderate sedation of pediatric dental patients.

Для цитирования: Kinard Bryce W, Zale Andrew S, Reed Kenneth L. Efficacy of Midazolam/Meperidine vs Midazolam/Hydromorphone for Enteral Moderate Sedation in the Pediatric Dental Patient.. Anesthesia progress. 2024. DOI: 10.2344/22-00037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.