DOI 10.1016/j.ejim.2023.09.026
ECG/echo indexes in the diagnostic approach to amyloid cardiomyopathy: A head-to-head comparison from the AC-TIVE study.
Аннотация
BACKGROUND AND AIMS: The discordance between QRS voltages on electrocardiogram (ECG) and left ventricle (LV) wall thickness (LVWT) on echocardiogram (echo) is a recognized red flag (RF) of amyloid cardiomyopathy (AC) and can be measured by specific indexes. No head-to-head comparison of different ECG/echo indexes among subjects with echocardiographic suspicion of AC has yet been undertaken. The study aimed at evaluating the performance and the incremental diagnostic value of different ECG/echo indexes in this subset of patients.
METHODS
Electrocardiograms of subjects with LV hypertrophy, preserved ejection fraction and ≥ 1 echocardiographic RF of AC participating in the AC-TIVE study, an Italian prospective multicenter study, were independently analyzed by two cardiologists. Low QRS voltages and 8 different ECG/echo indexes were evaluated. Cohort specific cut-offs were computed.
RESULTS
Among 170 patients, 55 (32 %) were diagnosed with AC. Combination of low QRS voltages with interventricular septum ≥ 1,6 cm was the most specific (specificity 100 %, positive predictive value 100 %) ECG/echo index, while the ratio between the sum of all QRS voltages and LVWT <7,8 was the most sensitive and accurate (sensitivity 94 %, negative predictive value 97 %, accuracy 82 %). When the latter index was added to a model using easily-accessible clinical variables, the diagnostic accuracy for AC greatly increased (AUC from 0,84 to 0,95; p = 0,007).
CONCLUSIONS
Among patients with non-dilated hypertrophic ventricles with normal ejection fraction and echocardiographic RF of AC, easily-measurable ECG/echo indexes, mainly when added to few clinical variables, can help the physician orient second level investigations. External validation of the results is warranted.