MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-023-03353-w

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023

Transthyretin amyloid cardiomyopathy disease burden quantified using 99mTc-pyrophosphate SPECT/CT: volumetric parameters versus SUVmax ratio at 1 and 3 hours.

Watanabe Satoru, Nakajima Kenichi, Toshima Fumihito, Wakabayashi Hiroshi, Yoshida Shohei, Yoneyama Hiroto, Komatsu Junji, Konishi Takahiro, Kinuya Seigo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Various parameters derived from technetium-99m pyrophosphate (99mTc-PYP) single-photon emission computed tomography (SPECT) correlate with the severity of transthyretin amyloid cardiomyopathy (ATTR-CM). However, the optimal metrics and image acquisition timing required to quantify the disease burden remain uncertain.

METHODS AND

RESULTS

We retrospectively evaluated 99mTc-PYP SPECT/CT images of 23 patients diagnosed with ATTR-CM using endomyocardial biopsies and/or gene tests. All patients were assessed by SPECT/CT 1 hour after 99mTc-PYP injection, and 13 of them were also assessed at 3 hours. We quantified 99mTc-PYP uptake using the volumetric parameters, cardiac PYP volume (CPV) and cardiac PYP activity (CPA). We also calculated the SUVmax ratios of myocardial SUVmax/blood pool SUVmax, myocardial SUVmax/bone SUVmax, and the SUVmax retention index. We assessed the correlations between uptake parameters and the four functional parameters associated with prognosis, namely left ventricular ejection fraction, global longitudinal strain, myocardial extracellular volume, and troponin T. CPV and CPA correlated more closely than the SUVmax ratios with the four prognostic factors. Significant correlations between volumetric parameters and prognostic factors were equivalent between 1 and 3 hours.

CONCLUSIONS

The disease burden of ATTR-CM was quantified more accurately by volumetric evaluation of 99mTc-PYP SPECT/CT than SUVmax ratios and the performance was equivalent between 1 and 3 hours.

Для цитирования: Watanabe Satoru, Nakajima Kenichi, Toshima Fumihito, Wakabayashi Hiroshi, Yoshida Shohei, Yoneyama Hiroto, Komatsu Junji, Konishi Takahiro, Kinuya Seigo. Transthyretin amyloid cardiomyopathy disease burden quantified using 99mTc-pyrophosphate SPECT/CT: volumetric parameters versus SUVmax ratio at 1 and 3 hours.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2023. DOI: 10.1007/s12350-023-03353-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.