MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2006.11.030

Медицинская библиотека · American journal of ophthalmology · 2006

Evaluation of keratoconus in Asians: role of Orbscan II and Tomey TMS-2 corneal topography.

Lim Li, Wei Rui Hua, Chan Wing Kwong, Tan Donald T H

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the corneal topographic patterns of Asian patients with keratoconus (KC).

DESIGN

Prospective observational case-control study.

SETTING

Institutional.

STUDY POPULATION: A total of 116 patients (both eyes included) with KC were recruited. The control group consisted of 70 laser in-situ keratomileusis (LASIK) candidates with myopia. Patients with previous ocular surgery and trauma were excluded.

OBSERVATION PROCEDURE: Corneal topography was performed using the Tomey KC screening system (Topographic Modeling System, software version 2.4.2J, Tomey Corp, Nagoya, Japan) and Orbscan II corneal topography system (Bausch & Lomb Surgical, Orbtek Inc, Salt Lake City, Utah, USA).

MAIN OUTCOME MEASURES: Videokeratographic variables were analyzed and the eyes were grouped into KC, KC suspect, and control groups.

RESULTS

The corneal topographic patterns of 196 eyes were analyzed. The topographic patterns displayed by Tomey (TMS-2N) and Orbscan II were similar. The majority of eyes with KC (71.2%) and KC suspect (70%) had asymmetric bowtie patterns. Thirteen indices of TMS-2N were analyzed and the means of the indices were found to be significantly higher in eyes in the KC group than the KC suspect group (P < .001). Fourteen indices of Orbscan II were analyzed. Eyes in the KC suspect group had higher mean posterior elevation (46 +/- 17 microm), 3 mm irregularity (2.44 +/- 1.36 diopters [D]), 5 mm irregularity (2.61 +/- 1.19 D) and had thinner corneas (mean 504.4 +/- 40.4 microm) than normal eyes (26 +/- 8 microm, 1.05 +/- 0.37 D, 1.38 +/- 0.39 D, and 554.0 +/- 25.0 microm, respectively).

CONCLUSION

Corneal topography pattern recognition combined with quantitative diagnostic indices is useful for the screening and classification of KC with the Orbscan II being more sensitive in screening for KC than TMS-2N.

Для цитирования: Lim Li, Wei Rui Hua, Chan Wing Kwong, Tan Donald T H. Evaluation of keratoconus in Asians: role of Orbscan II and Tomey TMS-2 corneal topography.. American journal of ophthalmology. 2006. DOI: 10.1016/j.ajo.2006.11.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.