What is the sensitivity of mammography and dynamic MR imaging for DCIS if the whole-breast histopathology is used as a reference standard?
Аннотация
PURPOSE: Our purpose was to compare mammography and dynamic contrast-enhanced magnetic resonance imaging (MRI) in the detection of ductal carcinoma in situ (DCIS).
MATERIALS AND
METHODS
Ninety patients (aged 58.6+/-16.1 years) who were candidates for unilateral (n=81) or bilateral (n=9) mastectomy underwent mammography and dynamic contrast-enhanced breast MRI using a coronal three-dimensional gradient-echo sequence with slice thickness < or =3 mm before and after intravenous injection of gadoteridol (0.1 mmol/kg). Mammographic and MR images were evaluated by two offsite readers working in consensus. Pathological examination performed on 5-mm sections covering the whole breast was used as a reference standard.
RESULTS
Out of 99 breasts, pathology revealed 26 DCIS in 14 breasts of 14 patients, aged 52.0 +/- 9.6 years. Lesion diameter at pathology was <5 mm (n=4); > or =5 and <10 mm (n=7); > or =10 and <20 mm (n=3); > or =20 mm (n=2); not assessed (n=10). Sensitivity was 35% (9/26) for mammography and 38% (10/26) for MRI (not significant difference, McNemar test). Both mammography and MRI provided a true positive result in seven cases (four of them measured at pathology, with a diameter of 20.0+/-12.9 mm; median 20 mm) and a false negative result in 14 cases (10 of them measured at pathology, with a diameter of 4.2+/-1.9 mm; median 4.6 mm) (p=0.024, Mann-Whitney U test). Only 46% (12/26) of DCIS were detected at mammography and/or MRI; the remaining 54% (14/26) were diagnosed only at pathological examination.
CONCLUSIONS
When the whole breast is used as the histopathological reference standard, both mammography and MRI show low sensitivity for DCIS.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.