MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/dmcn.14797

Медицинская библиотека · Developmental medicine and child neurology · 2021

Prevalence of long-term mechanical insufflation-exsufflation in children with neurological conditions: a population-based study.

Hov Brit, Andersen Tiina, Toussaint Michel, Vollsaeter Maria, Mikalsen Ingvild B, Indrekvam Solfrid, Hovland Vegard

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: To determine the prevalence of long-term mechanical insufflation-exsufflation (MI-E) and concomitant mechanical ventilation in children with neurological conditions, with reported reasons behind the initiation of treatment.

METHOD: This was a population-based, cross-sectional study using Norwegian national registries and a questionnaire.

RESULTS

In total, 114 of 19 264 children with a neurological condition had an MI-E device. Seventy-three of 103 eligible children (31 females, 42 males), median (min-max) age of 10 years 1 month (1y 5mo-17y 10mo), reported their MI-E treatment initiation. Overall, 76% reported airway clearance as the main reason to start long-term MI-E. A prophylactic use was mainly reported by children with neuromuscular disorders (NMDs). Prevalence and age at initiation differed by diagnosis. In spinal muscular atrophy and muscular dystrophies, MI-E use was reported in 34% and 7% of children, of whom 83% and 57% respectively received ventilator support. One-third of the MI-E users were children with central nervous system (CNS) conditions, such as cerebral palsy and degenerative disorders, and ventilator support was provided in 31%. The overall use of concomitant ventilatory support among the long-term MI-E users was 56%.

INTERPRETATION: The prevalence of MI-E in a neuropaediatric population was 6 per 1000, with two-thirds having NMDs and one-third having conditions of the CNS. The decision to initiate MI-E in children with neurological conditions relies on clinical judgment.

WHAT THIS PAPER ADDS: The prevalence and age at initiation of mechanical insufflation/exsufflation (MI-E) differed between diagnoses. MI-E was most commonly used in spinal muscular atrophy, where it generally coincided with ventilatory support. One-third of MI-E devices were given to children with central nervous system conditions, and one-third also received ventilatory support.

Для цитирования: Hov Brit, Andersen Tiina, Toussaint Michel, Vollsaeter Maria, Mikalsen Ingvild B, Indrekvam Solfrid, Hovland Vegard. Prevalence of long-term mechanical insufflation-exsufflation in children with neurological conditions: a population-based study.. Developmental medicine and child neurology. 2021. DOI: 10.1111/dmcn.14797.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.