MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.5c04161

Медицинская библиотека · ACS sensors · 2026

Ligand-Based Computational Design and Preclinical Evaluation of a Novel Cyclic Peptide Radiotracer for FGFR1-Targeted PET Imaging in Uveal Melanoma.

Wang Ling, Zhu Xue, Yu Mengxi, Zhu Hong, Huang Zhihong, Xue Yan, Wang Shuang, Jiao Yang, Li Yonghao, Lian Bin, Xu Chunwei, Hao Yue, Fang Jing, Wang Ke

СтатьяПеревод пока не подготовлен

Аннотация

Uveal melanoma (UM), a rare yet aggressive ocular malignancy in adults, highlights the critical need for targeted therapies to improve clinical outcomes. Elevated FGFR1 expression in UM correlates with aggressive disease progression and poor survival outcomes, underscoring its therapeutic value. This study reports the development of [68Ga]Ga-DOTA-cHW8, an FGFR1-specific PET tracer derived from ligand-based computational design of cyclic peptide cHW8, enabling noninvasive quantification of FGFR1 expression in UM xenograft models. Bioinformatics analysis of clinical databases and immunoblotting of clinical specimens confirmed FGFR1 as an important biomarker of UM. The radiotracer [68Ga]Ga-DOTA-cHW8 demonstrated superior pharmacokinetics with rapid tumor accumulation, high binding specificity, and rapid renal clearance. In vitro specificity assays demonstrated targeted accumulation of [68Ga]Ga-DOTA-cHW8 in FGFR1-positive 92.1 cells and UM PDC cells. In vivo microPET imaging validated tumor-specific accumulation of [68Ga]Ga-DOTA-cHW8 in FGFR1-positive UM xenografts (including PDX models), which was blocked by an unlabeled peptide. Furthermore, [68Ga]Ga-DOTA-cHW8 validated FGFR1 dynamic modulation during erdafitinib treatment in CDX and PDX models, establishing its efficacy for noninvasive UM treatment response assessment. This study reports a cyclic peptide-based radiotracer, [68Ga]Ga-DOTA-cHW8, for FGFR1 PET imaging in UM. Through rational design and preclinical validation in UM models, we establish its high specificity, favorable pharmacokinetics properties, and capability to monitor FGFR1 dynamics during targeted therapy.

Для цитирования: Wang Ling, Zhu Xue, Yu Mengxi, Zhu Hong, Huang Zhihong, Xue Yan, Wang Shuang, Jiao Yang, Li Yonghao, Lian Bin, Xu Chunwei, Hao Yue, Fang Jing, Wang Ke. Ligand-Based Computational Design and Preclinical Evaluation of a Novel Cyclic Peptide Radiotracer for FGFR1-Targeted PET Imaging in Uveal Melanoma.. ACS sensors. 2026. DOI: 10.1021/acssensors.5c04161.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.