MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.resuscitation.2012.08.335

Медицинская библиотека · Resuscitation · 2012

American Heart Association cardiopulmonary resuscitation quality targets are associated with improved arterial blood pressure during pediatric cardiac arrest.

Sutton Robert M, French Benjamin, Nishisaki Akira, Niles Dana E, Maltese Matthew R, Boyle Lori, Stavland Mette, Eilevstjønn Joar, Arbogast Kristy B, Berg Robert A, Nadkarni Vinay M

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate the association between cardiopulmonary resuscitation (CPR) quality and hemodynamic measurements during in-hospital pediatric cardiac arrest. We hypothesized that AHA recommended CPR rate and depth targets would be associated with systolic blood pressures≥80mmHg and diastolic blood pressures≥30mmHg.

METHODS

In children and adolescents <18 years of age who suffered a cardiac arrest with an invasive arterial catheter in place, a CPR monitoring defibrillator collected CPR data which was synchronized to arterial blood pressure (BP) tracings. Chest compression (CC) depths were corrected for mattress deflection. Generalized least squares regression estimated the association between BP and CPR quality, treated as continuous variables. Mixed-effects logistic regression estimated the association between systolic BP≥80mmHg/diastolic BP≥30mmHg and the AHA targets of depth≥38mm and/or rate≥100/min.

RESULTS

Nine arrests resulted in 4156 CCs. The median mattress corrected depth was 32mm (IQR 28-38); median rate was 111CC/min (IQR 103-120). AHA depth was achieved in 1090/4156 (26.2%) CCs; rate in 3441 (83.7%). Systolic BP≥80mmHg was attained in 2516/4156 (60.5%) compressions; diastolic≥30mmHg in 2561/4156 (61.6%). A rate≥100/min was associated with systolic BP≥80mmHg (OR 1.32; CI(95) 1.04, 1.66; p=0.02) and diastolic BP≥30mmHg (OR 2.15; CI(95) 1.65, 2.80; p<0.001). Exceeding both (rate≥100/min and depth≥38mm) was associated with systolic BP≥80mmHg (OR 2.02; CI(95) 1.45, 2.82; p<0.001) and diastolic BP≥30mmHg (OR 1.48; CI(95) 1.01, 2.15; p=0.042).

CONCLUSIONS

AHA quality targets (rate≥100/min and depth≥38mm) were associated with systolic BPs≥80mmHg and diastolic BPs≥30mmHg during CPR in children.

Для цитирования: Sutton Robert M, French Benjamin, Nishisaki Akira, Niles Dana E, Maltese Matthew R, Boyle Lori, Stavland Mette, Eilevstjønn Joar, Arbogast Kristy B, Berg Robert A, Nadkarni Vinay M. American Heart Association cardiopulmonary resuscitation quality targets are associated with improved arterial blood pressure during pediatric cardiac arrest.. Resuscitation. 2012. DOI: 10.1016/j.resuscitation.2012.08.335.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.