MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.15-18667

Медицинская библиотека · Investigative ophthalmology & visual science · 2016

Comparing Optic Nerve Head Rim Width, Rim Area, and Peripapillary Retinal Nerve Fiber Layer Thickness to Axon Count in Experimental Glaucoma.

Fortune Brad, Hardin Christy, Reynaud Juan, Cull Grant, Yang Hongli, Wang Lin, Burgoyne Claude F

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We compare spectral-domain optical coherence tomography (SDOCT) measurements of minimum rim width (MRW), minimum rim area (MRA), and peripapillary retinal nerve fiber layer thickness (RNFLT) to complete orbital optic nerve axon counts in nonhuman primates (NHP) with unilateral experimental glaucoma (EG).

METHODS

Biweekly SDOCT measurements of MRW, MRA, and RNFLT were acquired under manometric IOP control (10 mm Hg) in 51 NHP during baseline (mean ± SD, 5.0 ± 1.6 sessions) and after laser photocoagulation was applied to the trabecular meshwork of one eye to induce chronic IOP elevation. At the study endpoint (predefined for each NHP), 100% axon counts were obtained from each optic nerve.

RESULTS

For SDOCT parameters at baseline, the correlation between the two eyes of each animal was strongest for RNFLT (R = 0.97) and MRW (R = 0.97), but lower for MRA (R = 0.85). At the final time point, average values in EG eyes relative to control eyes were: -22% for RNFLT, -38% for MRW, -36% for MRA, and -36% for optic nerve axons. The correlation with axon counts was strongest for RNFLT (R = 0.81), compared to MRW (R = 0.72, P = 0.001) or MRA (R = 0.70, P = 0.001). Diagnostic sensitivity was 75% for RNFLT, 90% for MRW, and 88% for MRA; all had 100% specificity.

CONCLUSIONS

Peripapillary RNFLT was correlated more closely with total orbital optic nerve axon count than were the ONH parameters MRW or MRA. This is likely because glaucomatous deformation (beyond axon loss alone) has a greater influence on the ONH parameters MRW and MRA than on RNFLT.

Для цитирования: Fortune Brad, Hardin Christy, Reynaud Juan, Cull Grant, Yang Hongli, Wang Lin, Burgoyne Claude F. Comparing Optic Nerve Head Rim Width, Rim Area, and Peripapillary Retinal Nerve Fiber Layer Thickness to Axon Count in Experimental Glaucoma.. Investigative ophthalmology & visual science. 2016. DOI: 10.1167/iovs.15-18667.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.