Innovative Nb2CTx MXene nanomaterial-supported MIP sensor for detection of HIF-PHI inhibitor roxadustat in biological and pharmaceutical samples.

Gharibi Mahdi, Cetinkaya Ahmet, Gurbuz Havva Nur, Uzunoglu Aytekin, Bellur Atici Esen, Ozkan Sibel A

СтатьяПеревод в очереди

Аннотация

Roxadustat (ROX), a hypoxia-inducible factor prolyl hydroxylase inhibitor (HIF-PHI), effectively treats anemia in chronic kidney disease (CKD) by increasing hemoglobin levels by activating the body's natural hypoxic response. This work details the development and manufacturing of an electrochemical sensor based on molecularly imprinted polymers (MIP) and supported by MXene for the detection of ROX. Additionally, MIP-based sensors were created to identify ROX in standard solutions and biological samples. In the MIP-based electrochemical sensor developed using the photopolymerization (PP) method on the glassy carbon electrode (GCE) surface were utilized 2-dimensional Nb2CTx MXene (2D Nb2CTx) as a pore former, 3-amino phenylboronic acid (3-APBA) served as the functional monomer, and ROX as the template molecule. Under optimized experimental conditions, the designed sensor exhibited a linearity range of 1.0 × 10-13 - 1.0 × 10-12 M. Interference studies confirmed the superior selectivity of the MIP-based sensor for ROX, demonstrating its effectiveness in various binary mixtures. The recovery values of the MIP-based sensors were found to be 100.80% for commercial tablet samples and 99.53% for commercial serum samples. Moreover, the relative selectivity coefficient (k') of the proposed sensor was calculated. This recently designed sensor provides a promising method for quickly, sensitively, economically, and selectively analyzing ROX. The results obtained in high selectivity and recovery studies make the developed sensor a valuable tool for various applications in clinical and pharmaceutical environments. In addition, this study achieved better sensitivity than other studies in the literature and is the first electrochemical sensor prepared using Nb2CTx MXene nanomaterials-supported MIP technology for ROX measurement.

Для цитирования: Gharibi Mahdi, Cetinkaya Ahmet, Gurbuz Havva Nur, Uzunoglu Aytekin, Bellur Atici Esen, Ozkan Sibel A. Innovative Nb2CTx MXene nanomaterial-supported MIP sensor for detection of HIF-PHI inhibitor roxadustat in biological and pharmaceutical samples.. Talanta. 2025. DOI: 10.1016/j.talanta.2025.128573.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.