Archives of disease in childhood · 1999
Left ventricular diastolic function in congenital myotonic dystrophy.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bu'Lock F A, Sood M, De Giovanni J V, Green S H
Аннотация
OBJECTIVE: Examination of left ventricular function and conduction abnormalities in myotonic dystrophy.
DESIGN: Twelve patients (median age, 13.7 years) with myotonic dystrophy had detailed electrocardiography and echocardiography performed. Echocardiographic parameters were compared with body surface area (BSA) matched median normal values.
RESULTS: Fractional shortening was slightly reduced (by 28-29%) in three patients and three patients had mild mitral valve prolapse. Diastolic function was abnormal; isovolumic relaxation time (IVRT) and duration of early filling were prolonged compared with control values (median IVRT, 74 v 61 ms). Peak E velocity was increased (median, 0.82 v 0.78 m/s) but atrial phase filling was normal. Heart rate was reduced (median, 68 v 81 beats/min). Conduction abnormalities were common but showed no clear relations with diastolic abnormalities.
CONCLUSIONS: Young patients with myotonic dystrophy have myocardial diastolic dysfunction as well as abnormal electrophysiology. The prognostic implications of such abnormalities require further study.
DESIGN: Twelve patients (median age, 13.7 years) with myotonic dystrophy had detailed electrocardiography and echocardiography performed. Echocardiographic parameters were compared with body surface area (BSA) matched median normal values.
RESULTS: Fractional shortening was slightly reduced (by 28-29%) in three patients and three patients had mild mitral valve prolapse. Diastolic function was abnormal; isovolumic relaxation time (IVRT) and duration of early filling were prolonged compared with control values (median IVRT, 74 v 61 ms). Peak E velocity was increased (median, 0.82 v 0.78 m/s) but atrial phase filling was normal. Heart rate was reduced (median, 68 v 81 beats/min). Conduction abnormalities were common but showed no clear relations with diastolic abnormalities.
CONCLUSIONS: Young patients with myotonic dystrophy have myocardial diastolic dysfunction as well as abnormal electrophysiology. The prognostic implications of such abnormalities require further study.