The Laryngoscope · 2019
Intersegmenter Variability in High-Speed Laryngoscopy-Based Glottal Area Waveform Measures.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Maryn Youri, Verguts Monique, Demarsin Hannelore, van Dinther Joost, Gomez Pablo, Schlegel Patrick, Döllinger Michael
Аннотация
OBJECTIVES/HYPOTHESIS: High-speed videoendoscopy (HSV) has potential to objectively quantify vibratory vocal fold characteristics during phonation. Glottal Analysis Tools (GAT) version 2018, developed in Erlangen, Germany, is software for determining various glottal area waveform (GAW) quantities. Before having GAT analyze HSV videos, segmenters have to define glottis manually across videos in a semiautomatic segmentation protocol. Such interventions are hypothesized to induce variability of subsequent GAW measure computation across segmenters and may attenuate GAT measures' reliability to a certain point. This study explored intersegmenter variability in GAT's GAW measures based on semiautomatic image processing.
STUDY DESIGN: Cohort study of rater reliability.
METHODS: In total, 20 HSV videos from normophonic and dysphonic subjects with various laryngeal disorders were selected for this study and segmented by three trained segmenters. They separately segmented glottis areas in the same frame sets of the videos. Upon analysis of GAW, GAT offers 46 measures related to topologic GAW dynamic characteristics, GAW periodicity and perturbation characteristics, and GAW harmonic components. To address GAT's reliability, intersegmenter-based variability in these measures was examined with intraclass correlation coefficient (ICC).
RESULTS: In general, ICC behavior of the 46 GAW measures across three raters was highly acceptable. ICC of one parameter was moderate (0.5 < ICC < 0.75), good for seven parameters (0.75 < ICC < 0.9), and excellent for 38 parameters (0.9 < ICC).
CONCLUSIONS: Overall, high ICC values confirm clinical applicability of GAT for objective and quantitative assessment of HSV. Small intersegmenter differences with actual small parameter differences suggest that manual or semiautomatic segmentation in GAT does not noticeably influence clinical assessment outcome. To guarantee the software's performance, we suggest segmentation training before clinical application.
LEVEL OF EVIDENCE: 2b Laryngoscope, 130:E654-E661, 2020.
STUDY DESIGN: Cohort study of rater reliability.
METHODS: In total, 20 HSV videos from normophonic and dysphonic subjects with various laryngeal disorders were selected for this study and segmented by three trained segmenters. They separately segmented glottis areas in the same frame sets of the videos. Upon analysis of GAW, GAT offers 46 measures related to topologic GAW dynamic characteristics, GAW periodicity and perturbation characteristics, and GAW harmonic components. To address GAT's reliability, intersegmenter-based variability in these measures was examined with intraclass correlation coefficient (ICC).
RESULTS: In general, ICC behavior of the 46 GAW measures across three raters was highly acceptable. ICC of one parameter was moderate (0.5 < ICC < 0.75), good for seven parameters (0.75 < ICC < 0.9), and excellent for 38 parameters (0.9 < ICC).
CONCLUSIONS: Overall, high ICC values confirm clinical applicability of GAT for objective and quantitative assessment of HSV. Small intersegmenter differences with actual small parameter differences suggest that manual or semiautomatic segmentation in GAT does not noticeably influence clinical assessment outcome. To guarantee the software's performance, we suggest segmentation training before clinical application.
LEVEL OF EVIDENCE: 2b Laryngoscope, 130:E654-E661, 2020.