Indian journal of ophthalmology · 2022
Effects of low-concentration atropine eye drops on the optical quality of the eyes in myopic children.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Li Weiran, Cao Yiting, Zhou Jibo
Аннотация
PURPOSE: The present study was performed to compare the optical quality of the eyes of myopic children before and after treatment with atropine eye drops of different concentrations.
METHODS: In the study population of 71 patients (131 eyes), 34 patients (63 eyes) were given 0.01% atropine eye drops and 37 patients (68 eyes) were given 0.05% atropine eye drops. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs 100%, 20%, and 9%) under different lighting conditions were measured before and after two weeks of atropine treatment.
RESULTS: After using 0.05% atropine eye drops for two weeks, the Strehl ratio decreased from 0.27 ± 0.07 to 0.23 ± 0.07 (P = 0.0026), PVA 20% decreased from 1.15 ± 0.32 to 1.03 ± 0.36 (P = 0.0344), and PVA 9% decreased from 0.74 ± 0.23 to 0.64 ± 0.23 (P = 0.0073). The OSI was significantly higher after using 0.05% than 0.01% atropine eye drops (P = 0.0396), while both the Strehl ratio and PVA 20% were lower after using 0.05% than 0.01% atropine eye drops (P = 0.0087 and P = 0.0492, respectively).
CONCLUSION: The children's optical quality did not change significantly after using 0.01% atropine eye drops, whereas it decreased after using 0.05% atropine eye drops.
METHODS: In the study population of 71 patients (131 eyes), 34 patients (63 eyes) were given 0.01% atropine eye drops and 37 patients (68 eyes) were given 0.05% atropine eye drops. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs 100%, 20%, and 9%) under different lighting conditions were measured before and after two weeks of atropine treatment.
RESULTS: After using 0.05% atropine eye drops for two weeks, the Strehl ratio decreased from 0.27 ± 0.07 to 0.23 ± 0.07 (P = 0.0026), PVA 20% decreased from 1.15 ± 0.32 to 1.03 ± 0.36 (P = 0.0344), and PVA 9% decreased from 0.74 ± 0.23 to 0.64 ± 0.23 (P = 0.0073). The OSI was significantly higher after using 0.05% than 0.01% atropine eye drops (P = 0.0396), while both the Strehl ratio and PVA 20% were lower after using 0.05% than 0.01% atropine eye drops (P = 0.0087 and P = 0.0492, respectively).
CONCLUSION: The children's optical quality did not change significantly after using 0.01% atropine eye drops, whereas it decreased after using 0.05% atropine eye drops.