MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/opo.12981

Медицинская библиотека · Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2022

Manual and software-based measurements of treatment zone parameters and characteristics in children with slow and fast axial elongation in orthokeratology.

Guo Biyue, Wu Huihuan, Cheung Sin Wan, Cho Pauline

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the treatment zone (TZ) measurements obtained using manual and software-based methods in orthokeratology (ortho-k) subjects and explore the TZ characteristics of children with slow and fast axial elongation after ortho-k.

METHODS

Data from 69 subjects (aged 7 to <13 years old), who participated in three 24-month longitudinal orthokeratology studies, showing fast (>0.27 mm, n = 38) and slow (<0.09 mm, n = 31) axial elongation, were retrieved. The TZ after ortho-k was defined as the central flattened area enclosed by points with no refractive power change. TZ parameters, including decentration, size, width of the peripheral steepened zone (PSZ), central and peripheral refractive power changes and peripheral rate of power change, were determined manually and using python-based software. TZ parameters were compared between measurement methods and between groups.

RESULTS

Almost all TZ parameters measured manually and with the aid of software were significantly different (p < 0.05). Differences in decentration, size and the PSZ width were not clinically significant, but differences (0.45 to 0.92 D) in refractive power change in the PSZ were significant, although intraclass coefficients (0.95 to 0.98) indicated excellent agreement between methods. Significantly greater TZ decentration, smaller TZ size and greater inferior rate of power change (relative to the TZ centre) were observed in slow progressors using both methods, suggesting a potential role of TZ in regulating myopia progression in ortho-k.

CONCLUSION

TZ measurements using manual and software-based methods differed significantly and cannot be used interchangeably. The combination of TZ decentration, TZ size and peripheral rate of power change may affect myopia control effect in ortho-k.

Для цитирования: Guo Biyue, Wu Huihuan, Cheung Sin Wan, Cho Pauline. Manual and software-based measurements of treatment zone parameters and characteristics in children with slow and fast axial elongation in orthokeratology.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2022. DOI: 10.1111/opo.12981.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.