MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2009.09.024

Медицинская библиотека · Ophthalmology · 2010

Short-term visual outcomes of Boston type 1 keratoprosthesis implantation.

Dunlap Karen, Chak Garrick, Aquavella James V, Myrowitz Elliott, Utine Canan Asli, Akpek Esen

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To report the short-term visual outcomes after keratoprosthesis implantation.

DESIGN

Retrospective multi center case series (Wilmer Eye Institute and University of Rochester Eye Institute).

PARTICIPANTS

One hundred twenty-two patients (126 eyes) with corneal diseases that were deemed ineligible to receive donor corneal transplants.

INTERVENTION: Patients underwent a Boston type I keratoprosthesis procedure for visual rehabilitation.

MAIN OUTCOME MEASURES: The medical records of the patients were reviewed to assess intraoperative and postoperative complications, uncorrected and best-corrected visual acuity, as well as the degree of refractive error at various time points.

RESULTS

One hundred four patients (82.5%) achieved improved vision within 6 months after surgery. An overwhelming majority of those patients who had improved vision had a manifest refraction of plano. The mean spherical refractive error was -0.57 diopters (D) and mean astigmatism was 0.10 D. Cumulatively, 7.1% patients achieved their best-corrected vision at 1 day, 24.6% at 1 week, and 70.6% at 3 months. The patients who achieved their best-corrected visual acuity after the first 3-month period most often were the ones who required multiple surgeries owing to preexisting or postoperative complications.

CONCLUSIONS

Boston keratoprosthesis seems to provide rapid visual recovery with excellent uncorrected acuity in the early postoperative period.

FINANCIAL DISCLOSURE(S): The authors have no proprietary or commercial interest in any of the materials discussed in this article.

Для цитирования: Dunlap Karen, Chak Garrick, Aquavella James V, Myrowitz Elliott, Utine Canan Asli, Akpek Esen. Short-term visual outcomes of Boston type 1 keratoprosthesis implantation.. Ophthalmology. 2010. DOI: 10.1016/j.ophtha.2009.09.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.