NMR in biomedicine · 2026

The Iseult Coil, a Hybrid RF Coil for the First Human Brain Images at 11.7 T: Receive Performance Comparison With a Twin Coil at 7 T.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Amadon Alexis, Gapais Paul-François, Ferrand Guillaume, Gras Vincent, Mauconduit Franck, Le Ster Caroline, Vignaud Alexandre, Boulant Nicolas, Luong Michel

Аннотация

The Iseult scanner delivered the first human brain images at 11.7 T. Here, we bring forth the design of the RF coil used for these acquisitions, featuring 8 transmit and 32 receive channels, then evaluate its SNR and g-factor advantages with respect to a similar coil at 7 T. We attempt a deduction of the SNR dependency on field strength. First, we modeled our two compact coils for integration in a tight B 0 local shimming device. Electromagnetic simulation results on two different anatomical phantoms (one male and one female) were used for SAR/VOP, B1+, SNR- and g-map predictions. Simulations were calibrated with acquisitions on a spherical agar phantom, and SNR measurements were based on a 3D-GRE sequence. One volunteer was scanned at 7 and 11.7 T for that purpose, allowing a preliminary evaluation of α in the B 0 α -SNR model. Both coils performed as expected from simulations provided some corrections. For the agar sphere, we found a global intrinsic SNR gain of 2.75 between 7 and 11.7 T, corresponding to α ~ 1.95 . In contrast the gain in the human brain was about 2.2, corresponding to α ~ 1.5 , slightly less than previous results in the literature. Even though higher values are expected for an aqueous phantom because of its higher permittivity (increasing SNR thanks to the dielectric focusing effect), the main difference could be explained by physiological noise. As expected, the shorter wavelength induced by a higher B 0 also results in a perceptible but limited reduction of g-factors in simulations and measurements. In conclusion, this study highlighted the benefits of a high B 0 in reception, without the potential bias of a different RF coil design; these benefits come with a slight decrease in transmission efficiency (due to additional losses in brain tissue at high frequencies) and a greater difficulty in homogenizing spin excitation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты