MedElevator Войти в исследования
← Поиск публикаций

DOI 10.33963/kp.a2022.0124

Медицинская библиотека · Kardiologia polska · 2022

A prospective case-control validation of procalcitonin as a biomarker diagnosing pacemaker and implantable cardioverter-defibrillator pocket infection.

Knoll Katharina, O'Connor Matthew, Chouchane Amir, Haller Bernhard, Schaarschmidt Claudia, Bock Matthias, Förschner Leonie, Fröhlich Rebecca, Kottmaier Marc, Bourier Felix, Reents Tilko, Hessling Gabriele, Deisenhofer Isabel, Kolb Christof, Lennerz Carsten

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The diagnosis of device infections, especially pocket infections, is challenging and relies primarily on clinical presentation. The prospective DIRT (Device associated Infections Role of new diagnostic Tools) study identified procalcitonin (PCT) as the most promising biomarker among other 14 biomarkers to aid the diagnosis of pocket infection. It also identified an optimized cut-off value of 0.05 ng/ml for a localized generator pocket infection.

AIMS: The present study aims to validate the proposed PCT cut-off value of 0.05 ng/ml for the diagnosis of pocket infection in an independent cohort.

METHODS

We prospectively enrolled 81 patients with pocket infections and 81 controls matched for age and renal function presenting for elective device exchange or lead revision. Patients with concomitant infectious or inflammatory diseases, end-stage renal failure, current active malignancy, or receiving immunosuppressive therapy were excluded.

RESULTS

An elevated PCT over 0.05 ng/ml was found in 68% (n = 55) of pocket infections and 24% (n = 19) of controls, corresponding to a sensitivity of 68% and a specificity of 77% for diagnosing a pocket infection. In receiver operating characteristic (ROC) analysis, PCT showed an area under the curve of 0.75 (95% confidence interval, 0.68-0.83; P < 0.001). Sensitivity remained high with antibiotic pretreatment (65% compared to 69% without pretreatment) and in cases with minimal inflammatory signs (67% compared to 70% with extensive inflammation).

CONCLUSION

Our study validates the cut-off value of 0.05 ng/ml PCT for diagnosis of a pocket infection, even in patients pre-treated with antibiotics or with minimal clinical signs of inflammation.

Для цитирования: Knoll Katharina, O'Connor Matthew, Chouchane Amir, Haller Bernhard, Schaarschmidt Claudia, Bock Matthias, Förschner Leonie, Fröhlich Rebecca, Kottmaier Marc, Bourier Felix, Reents Tilko, Hessling Gabriele, Deisenhofer Isabel, Kolb Christof, Lennerz Carsten. A prospective case-control validation of procalcitonin as a biomarker diagnosing pacemaker and implantable cardioverter-defibrillator pocket infection.. Kardiologia polska. 2022. DOI: 10.33963/kp.a2022.0124.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.