Management of deep brain stimulator battery failure: battery estimators, charge density, and importance of clinical symptoms.

Fakhar Kaihan, Hastings Erin, Butson Christopher R, Foote Kelly D, Zeilman Pam, Okun Michael S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

We aimed in this investigation to study deep brain stimulation (DBS) battery drain with special attention directed toward patient symptoms prior to and following battery replacement.

BACKGROUND

Previously our group developed web-based calculators and smart phone applications to estimate DBS battery life (http://mdc.mbi.ufl.edu/surgery/dbs-battery-estimator).

METHODS

A cohort of 320 patients undergoing DBS battery replacement from 2002-2012 were included in an IRB approved study. Statistical analysis was performed using SPSS 20.0 (IBM, Armonk, NY).

RESULTS

The mean charge density for treatment of Parkinson's disease was 7.2 µC/cm(2)/phase (SD = 3.82), for dystonia was 17.5 µC/cm(2)/phase (SD = 8.53), for essential tremor was 8.3 µC/cm(2)/phase (SD = 4.85), and for OCD was 18.0 µC/cm(2)/phase (SD = 4.35). There was a significant relationship between charge density and battery life (r = -.59, p<.001), as well as total power and battery life (r = -.64, p<.001). The UF estimator (r = .67, p<.001) and the Medtronic helpline (r = .74, p<.001) predictions of battery life were significantly positively associated with actual battery life. Battery status indicators on Soletra and Kinetra were poor predictors of battery life. In 38 cases, the symptoms improved following a battery change, suggesting that the neurostimulator was likely responsible for symptom worsening. For these cases, both the UF estimator and the Medtronic helpline were significantly correlated with battery life (r = .65 and r = .70, respectively, both p<.001).

CONCLUSIONS

Battery estimations, charge density, total power and clinical symptoms were important factors. The observation of clinical worsening that was rescued following neurostimulator replacement reinforces the notion that changes in clinical symptoms can be associated with battery drain.

Для цитирования: Fakhar Kaihan, Hastings Erin, Butson Christopher R, Foote Kelly D, Zeilman Pam, Okun Michael S. Management of deep brain stimulator battery failure: battery estimators, charge density, and importance of clinical symptoms.. PloS one. 2013. DOI: 10.1371/journal.pone.0058665.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.