Impact of four-dimensional computed tomography phase number on target coverage of four-dimensional robustly optimized lung stereotactic body radiotherapy.

Yagihashi Takayuki, Inoue Tatsuya, Yamanaka Masashi, Shiba Shintaro, Yamano Akihiro, Sato Naoki, Minagawa Yumiko, Omura Motoko

СтатьяПеревод пока не подготовлен

Аннотация

This study evaluated the dosimetric benefits of various four-dimensional (4D) robust optimization strategies for enhancing plan robustness in free-breathing stereotactic body radiotherapy (SBRT). For ten early-stage lung cancer patients, we generated four helical tomotherapy-SBRT plans (42 Gy/4 fractions) using 4D robust optimization based on 4D-computed tomography (CT) images from all ten phases (4D_10), six phases (4D_6), four phases (4D_4), and two phases (4D_2). Conventional internal target volume (ITV)-based plans served as a reference. Setup uncertainty robustness was assessed across all CT phases. We compared dose and target coverage (D98%, V100%) for the gross tumor volume, doses to relevant organs at risk (OARs), and reductions in plan robustness for both nominal and perturbed scenarios. Optimization durations were recorded. All nominal plans met clinical criteria for targets and OARs. The 4D_10 plans exhibited the highest robustness in target coverage, with D98% significantly different from ITV plans (p < 0.05) and V100% significantly different from 4D_2 plans (p < 0.05). Optimization time increased linearly with the number of CT phases. Four-dimensional robust optimization enables free-breathing SBRT plans resilient to respiratory and setup uncertainties; however, limiting phase number may compromise robustness for certain tumors despite shorter optimization times.

Для цитирования: Yagihashi Takayuki, Inoue Tatsuya, Yamanaka Masashi, Shiba Shintaro, Yamano Akihiro, Sato Naoki, Minagawa Yumiko, Omura Motoko. Impact of four-dimensional computed tomography phase number on target coverage of four-dimensional robustly optimized lung stereotactic body radiotherapy.. Scientific reports. 2025. DOI: 10.1038/s41598-025-23090-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.