MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12149-025-02126-4

Медицинская библиотека · Annals of nuclear medicine · 2025

Clinical implementation of voxel-based dosimetry using image-based RT-PHITS Monte Carlo simulations for 177Lu-DOTATATE radionuclide therapy.

Tantiwetchayanon Khajonsak, Matsubara Kosuke, Nuntue Chatnapa, Shibutani Takayuki, Konishi Takahiro, Wakabayashi Hiroshi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aimed to employ RadioTherapy extension of the Particle and Heavy Ion Transport code System (RT-PHITS) Monte Carlo (MC) simulation for estimating absorbed doses in target organs and tumors in patients administered with 177Lu-DOTATATE, using single-photon emission computed tomography/computed tomography (SPECT/CT) imaging.

METHODS

Quantitative SPECT/CT images were obtained from 17 patients across the abdominal region at four time points: approximately 4, 24, 72, and 120 h following the administration of 177Lu-DOTATATE. The liver, spleen, left and right kidneys, and total kidneys were automatically segmented on the CT images using the TotalSegmentator tool. Tumors were manually delineated based on SPECT/CT images. Image registration was performed using an Elastix-based method, with the first SPECT/CT time point serving as the reference. Voxel-level time-integrated activity (TIA) maps were created by fitting mono-exponential functions. These TIA maps, together with the reference CT images, were input into RT-PHITS to calculate dose distributions. The absorbed doses calculated by RT-PHITS were compared with those from IDAC-Dose 2.1 through two approaches: first, by using independently derived time-integrated activity coefficients (TIACs) from each method to assess the combined effects of kinetic modeling and dose calculation technique; second, by applying the same TIACs-obtained from time-integrated activity data-to both methods to isolate the influence of the dose calculation approach.

RESULTS

RT-PHITS yielded higher mean absorbed doses per unit of administered activity compared to IDAC-Dose. The relative differences ranged between 0.63% and 15.35%, with the right kidney showing the largest discrepancy. When the same time-integrated data were used for both RT-PHITS and IDAC-Dose, relative differences remained below 10.40%.

CONCLUSION

RT-PHITS is a capable tool for calculating absorbed doses in 177Lu-DOTATATE therapy. It consistently produced higher dose estimates than the organ-based method, emphasizing the benefits of patient-specific dosimetry, especially in organs that contain or are near tumors.

Для цитирования: Tantiwetchayanon Khajonsak, Matsubara Kosuke, Nuntue Chatnapa, Shibutani Takayuki, Konishi Takahiro, Wakabayashi Hiroshi. Clinical implementation of voxel-based dosimetry using image-based RT-PHITS Monte Carlo simulations for 177Lu-DOTATATE radionuclide therapy.. Annals of nuclear medicine. 2025. DOI: 10.1007/s12149-025-02126-4.