Usefulness of automated fragmented red blood cell percentage in the diagnosis of paediatric haemolytic uraemic syndrome.
Аннотация
INTRODUCTION
Presence of schistocytes in peripheral blood smear supporting haemolysis is important for diagnosis and decision-making in paediatric haemolytic uraemic syndrome (HUS). High observer dependency and requirement of expertise for peripheral smear evaluation propels us to think of other modalities to overcome these issues. We envisage that newer techniques like automated fragmented red blood cell percentage (FRC %), whose role has been described in transplant associated HUS and thrombotic thrombocytopenic purpura, can serve the purpose.
METHODS
Twenty-eight children with HUS after excluding secondary causes were enrolled in this study. Blood samples were analysed for FRC% at admission, using SYSMEX XN-1000 (Japan) haematology analyser, and simultaneously, schistocytes in peripheral smear were reported by a single expert haematopathologist.
RESULTS
Median age was 56 months ranging from 2 to 140 months. FRC% was elevated in 85.8% (n-24/28) with a mean of 4.56 ± 3.1%. FRC% had a sensitivity of 95.4% (C.I: 77.16% to 99.88%) in children who had FRC% >1.49% with an accuracy of 85.71% (C.I: 67.33% to 95.97%). However, specificity was only 50% (C.I: 11.81% to 88.19%) with a positive likelihood ratio of 1.91. Receiver-operator curve showed an AUC value of 0.841.
CONCLUSION
We suggest automated FRC% as a rapid and highly sensitive index for screening of paediatric HUS; however, a peripheral blood film examination is a must in cases with count >2% to avoid false positives as the index has low specificity.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.