MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Ophthalmic surgery and lasers · 1997

Laser trabeculoplasty: how little is enough?

Frenkel R E, Shin D H, Epstein D L, Hertzmark E, Bohn J L, Hong Y J

Клиническое исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

The optimal number of laser applications for argon laser trabeculoplasty in patients with primary open-angle glaucoma has not been established. The purpose of this study was to determine the fewest number of burns necessary for clinically effective intraocular pressure reduction for these patients.

PATIENTS AND

METHODS

Using a prospective, randomized, collaborative study, the authors examined the relationship between the number of laser trabeculoplasty burns and intraocular pressure for patients with primary open-angle glaucoma. A total of 122 patients received either 50 burns to half of the trabecular meshwork (group 1) or 35 burns to one third of the trabecular meshwork (group 2).

RESULTS

The mean baseline intraocular pressures were similar between group 1 (22.3 +/- 4.1 mm Hg [mean +/- SD]) and group 2 (22.8 +/- 5.0 mm Hg) (P = .58). Intraocular pressure reduction at 9 to 12 months, although significant in both groups (group 1: 4.4 +/- 3.0 mm Hg, P < .0001; group 2: 3.9 +/- 5.1 mm Hg, P < .0001), did not differ significantly between the two groups (P = .63).

CONCLUSION

This study demonstrated that 35 burns may be as clinically effective as 50 burns in reducing the intraocular pressure in primary open-angle glaucoma patients.

Для цитирования: Frenkel R E, Shin D H, Epstein D L, Hertzmark E, Bohn J L, Hong Y J. Laser trabeculoplasty: how little is enough?. Ophthalmic surgery and lasers. 1997.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.