Biodistribution, Dosimetry, and Pharmacokinetics of 68Ga-CBP8: A Type I Collagen-Targeted PET Probe.
Аннотация
The 68Ga-Collagen Binding Probe #8, 68Ga-CBP8, is a peptide-based, type I collagen-targeted probe developed for imaging of tissue fibrosis. The aim of this study was to determine the biodistribution, dosimetry, and pharmacokinetics of 68Ga-CBP8 in healthy human subjects.
Methods
Nine healthy volunteers (5 male and 4 female) underwent whole-body 68Ga-CBP8 PET/MRI using a Biograph mMR scanner. The subjects were imaged continuously for up to 2 h after injection of 68Ga-CBP8. A subset of subjects underwent an additional imaging session 2-3 h after probe injection. OLINDA/EXM software was used to calculate absorbed organ and effective dose estimates based on up to 17 regions of interest (16 for men) defined on T2-weighted MR images and copied to the PET images, assuming a uniform distribution of probe concentration in each region. Serial blood sampling up to 90 min after probe injection was performed to assess blood clearance and metabolic stability.
Results
The mean injected activity (±SD) of 68Ga-CBP8 was 220 ± 100 MBq (range, 113-434 MBq). No adverse effects related to probe administration were detected. 68Ga-CBP8 demonstrated an extracellular distribution with predominantly rapid renal clearance. Doses on the urinary bladder were 0.15 versus 0.19 mGy/MBq for men versus women. The highest absorbed doses for the rest of the organs were measured in the kidneys (0.078 vs. 0.088 mGy/MBq) and the liver (0.032 vs. 0.041 mGy/MBq). The mean effective dose was 0.018 ± 0.0026 mSv/MBq using a 1-h voiding model. The 68Ga-CBP8 signal in the blood demonstrated biexponential pharmacokinetics with an initial distribution half-life of 4.9 min (95% CI, 2.4-9.4 min) and a 72-min elimination half-life (95% CI, 47-130 min). The only metabolite observed had a long blood plasma half-life, suggesting protein-bound 68Ga.
Conclusion
68Ga-CBP8 displays favorable in-human characteristics and dosimetry similar to that of other gallium-based probes. 68Ga-CBP8 could therefore be used for noninvasive collagen imaging across a range of human fibrotic diseases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.