m+Medelevator.RU
← Поиск публикаций
Annals of clinical biochemistry · 2023

Concordance in COVID-19 serology, bone mineralization, and inflammatory analytes between venous and self-collected capillary blood samples exposed to various pre-analytical conditions.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hosseini Banafshe, Dasari Harika, Smyrnova Anna, Bourassa Claude, Leng Jing, Renaud Christian, Ducharme Francine M

Аннотация

BACKGROUND: The COVID-19 has led to a significant increase in demand for remote blood sampling in clinical trials. This study aims to ascertain the concordance between venous versus capillary samples, processed immediately or exposed to various pre-analytical conditions.

METHODS: Participants (≥12 years old) provided a venous blood sample (processed immediately) and capillary samples allocated to one of the following conditions: processed immediately or exposed to 12-, 24-, or 36-h delays at room temperature or 36-h delays with a freeze-thaw cycle. The analytes of interest included SARS-CoV-2 IgG, 25-hydroxy vitamin D (25(OH)D), alkaline phosphate (ALP), calcium (Ca), phosphate (Ph), and c-reactive protein (CRP). Paired samples were considered interchangeable if they met three criteria: minimal within-subject mean difference, 95% of values within desirable total errors, and inter-class correlation (ICC) > 0.90.

RESULTS: 90 participants (44.1% male) were enrolled. When comparing rapidly processed venous with capillary samples, 25(OH)D, ALP, and CRP met all three criteria; SARS-CoV-2 IgG met two criteria (mean difference and ICC); and Ca and Ph met one criterion (mean difference). When considering all three criteria, concentrations of 25(OH)D, CRP, and ALP remained unchanged after delays of up to 36 h; SARS-CoV-2 IgG met two criteria (mean difference and ICC); Ca and Ph met one criterion (mean difference).

CONCLUSION: These findings suggest that remote blood collection devices can be used to measure anti-SARS-CoV-2 IgG, 25(OH)D, CRP, and ALP. Further analysis is required to evaluate the interchangeability between venous and capillary testing in Ca and Ph levels, which are more sensitive to pre-analytical conditions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты