DOI 10.1097/opx.0b013e31819fa590

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2009

Standardized patient methodology to assess refractive error reproducibility.

Shah Rakhee, Edgar David F, Rabbetts Ronald, Harle Deacon E, Evans Bruce J W

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Standardized patient (SP) methodology is the gold standard for evaluating clinical practice. This approach was used to investigate the content of typical optometric eyecare in England and the reproducibility of refractive error measurement using prescriptions obtained by three SPs.

METHODS

The three SPs were independently examined by three to four expert optometric clinicians to obtain "benchmark" estimates of refractive error. One hundred two community optometrists consented to be visited by three SPs who were trained to provide accurate responses during the examinations. The spectacle prescriptions obtained by the SPs were analyzed for spherical equivalent refraction, spherical power and cylindrical power using astigmatic decomposition.

RESULTS

The spherical equivalent refractions were found to be within +/-0.25 D of the benchmark on average 81% of the time and within +/-0.50 D 97% of the time. The spherical power was within +/-0.25 D 90% of the time and within +/-0.50 D 98% of the time. The cylindrical power agreed within +/-0.25 D 93% of the time and within +/-0.50 D 100% of the time. Based on reproducibility limits data obtained for all six eyes, any two optometrists would differ in their estimation of spherical equivalent refraction by no more than 0.75 D in 95% of repeated measures. The astigmatic data (C0 and C45) show that optometrists will differ in their estimation of the C0 component by between 0.25 and 0.61 D and for the C45 component by between 0.22 and 0.47 D in 95% of repeated measures.

CONCLUSIONS

The agreement between our data and the results of other similar studies support the conclusions that subjective refractive findings are reproducible to approximately +/-0.75 D when performed by multiple optometrists in patients of different age groups and levels of ametropia. SPs are an effective way of measuring reproducibility of refractive error and should be considered for further comparative analysis in different age groups and different levels of ametropia.

Для цитирования: Shah Rakhee, Edgar David F, Rabbetts Ronald, Harle Deacon E, Evans Bruce J W. Standardized patient methodology to assess refractive error reproducibility.. Optometry and vision science : official publication of the American Academy of Optometry. 2009. DOI: 10.1097/opx.0b013e31819fa590.