Minimally Invasive Plate Osteosynthesis in Open Pediatric Tibial Fractures.

Özkul Emin, Gem Mehmet, Arslan Hüseyin, Alemdar Celil, Azboy İbrahim, Arslan Seher G

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study is to investigate the effectiveness and reliability of limited-contact locking plates in minimally invasive percutaneous osteosynthesis (MIPO) of the lateral tibia.

DESIGN

A retrospective study.

PATIENTS AND

METHODS

The retrospective study included 14 patients who were operatively treated with an MIPO technique due to open tibial fractures between 2006 and 2012. The patients were 11 males and 3 females with a mean age of 13.2 (range, 9 to 16) years. The patients were followed up for a mean period of 2.4 (range, 1 to 5) years. The mechanism of the injuries included a motor vehicle accident (n=11), a shotgun injury (n=2), and a fall from height (n=1). According to the Gustilo-Anderson classification, 10 patients had type I (72%), 2 had type II (14%), and 2 had type III (14%) open fractures.

RESULTS

The mean time to radiologic union was 18 (range, 11 to 32) weeks. No infection was detected that would require implant removal. No complications such as early epiphyseal closure, angulation, or limb-length inequality were observed.

CONCLUSIONS

Limited-contact locking plates in MIPO of the lateral tibia is an effective alternative method in the treatment of open pediatric tibial fractures.

LEVEL OF EVIDENCE: Level IV-therapeutic.

Для цитирования: Özkul Emin, Gem Mehmet, Arslan Hüseyin, Alemdar Celil, Azboy İbrahim, Arslan Seher G. Minimally Invasive Plate Osteosynthesis in Open Pediatric Tibial Fractures.. Journal of pediatric orthopedics. 2016. DOI: 10.1097/bpo.0000000000000451.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.