MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.otohns.2005.07.038

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2005

Endoscopic endonasal reduction of blowout fractures of the orbital floor.

Hinohira Yasuyuki, Yumoto Eiji, Shimamura Ichiro

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to document the usefulness of the endoscopic endonasal approach as a surgical treatment of isolated blowout fractures of the orbital floor.

STUDY

DESIGN

Retrospective study.

SETTING

Between 1997 and 2003, using only an endonasal endoscopic surgical approach, we operated on 62 patients complaining of diplopia due to isolated blowout fractures of the orbital floor. In order to perform the endonasal reduction surgery, supplemental septoplasty and/or submucous conchotomy were done. Immediately following the reduction and the fixation, eye traction tests were performed to confirm the ocular motility improvement. Tampon gauzes or balloon catheters were used for the temporal fixation to support the orbital floor.

RESULTS

Postoperatively, diplopia completely disappeared in 55 of the 62 patients (88.7%) that were followed over 6 months.

CONCLUSION

The high success rate with regard to diplopia indicates that the endoscopic endonasal approach may be an alternative to extranasal methods.

EBM RATING: B-3.

Для цитирования: Hinohira Yasuyuki, Yumoto Eiji, Shimamura Ichiro. Endoscopic endonasal reduction of blowout fractures of the orbital floor.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2005. DOI: 10.1016/j.otohns.2005.07.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.