MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/17085381211051486

Медицинская библиотека · Vascular · 2021

Endoleak outcomes with different stent-graft generations in a 25-years thoracic endovascular aortic repair experience.

Gennai Stefano, Leone Nicola, Maria Bartolotti Luigi A, Covic Tea, Lauricella Antonio, Andreoli Francesco, Saitta Giuseppe, Silingardi Roberto

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

To compare endoleak outcomes after thoracic endovascular aneurysm repair (TEVAR) with different stent-graft generations into long-term follow-up.

DESIGN

retrospective, observational, and single-center cohort study.

METHODS

TEVAR procedures performed between November 1995 and December 2020 were analyzed. The primary endpoint of this study was the freedom from endoleak (type I/III) in four stent-graft generations during the follow-up period. The first generation (GEN1) included: Vanguard; AneuRx and Talent; Stentor; Excluder; Endologix; EndoFit. The second generation (GEN2) included: TAG and TX. The third (GEN3) included: Relay Plus; Valiant Captivia; Zenith Alpha and custom-made. The fourth (GEN4) included: Relay Pro; Conformable C-TAG; Navion; E-Vita; Najuta; Nexus; standard and custom-made thoraco-abdominal devices. Nonaortic and aorta-related survival was considered as secondary outcome.

RESULTS

A total of 509 TEVAR were included with a 44.3 ± 42.5 months mean follow-up. Freedom from endoleak at 5 years was 65.6%, 61.4%, 76.2%, and 69.1% for GEN1, GEN2, GEN3, and GEN4, respectively (p = 0.368). The first two generations demonstrated a higher endoleak rate when compared with the two most recent ones (27.2 vs 18.2%, respectively; p = 0.043). GEN1 was an independent risk factor (p = 0.014) and GEN4 was an independent protective factor (p = 0.001) for endoleak. GEN1 was found to be a risk factor for type-Ia endoleak (p = 0.059). GEN4 demonstrated a protective association regarding type-Ib endoleak (p = 0.012). Overall survival was 75.3%, 44.4%, 27.2%, and 17.6% at 1, 5, 10, and 15 years, respectively. Survival distinguished as non-related versus aortic-related was 86.7% vs 23.5%, 52.7% vs 9.8%, 32.9% vs 2.0%, 21.2% vs 0% at 1, 5, 10, and 15 years, respectively (p< 0.000).

CONCLUSION

Endoleak occurred in a non-negligible percentage of TEVAR patients. A significant reduction of endoleak incidence over evolving stent-grafts generations was registered. Newer stent-graft generations demonstrated better long-term endoleak. Data about long-term outcomes require ongoing updates to prove both the reliability and the durability of newer stent-graft generations.

Для цитирования: Gennai Stefano, Leone Nicola, Maria Bartolotti Luigi A, Covic Tea, Lauricella Antonio, Andreoli Francesco, Saitta Giuseppe, Silingardi Roberto. Endoleak outcomes with different stent-graft generations in a 25-years thoracic endovascular aortic repair experience.. Vascular. 2021. DOI: 10.1177/17085381211051486.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.