Investigating glycogenosis type III patients with multi-parametric functional NMR imaging and spectroscopy.

Wary Claire, Nadaj-Pakleza Aleksandra, Laforêt Pascal, Claeys Kristl G, Carlier Robert, Monnet Aurélien, Fleury Servanne, Baligand Céline, Eymard Bruno, Labrune Philippe, Carlier Pierre G

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Debranching enzyme deficiency (Glycogen storage disease (GSD) type III) causes progressive muscle wasting myopathy. A comprehensive nuclear magnetic resonance study involving spectroscopy (NMRS) and imaging (NMRI) evaluated status and function of calf muscles in 18 GSDIII patients. At rest, (31)P NMRS showed elevated pH and accumulation of anomalous phosphomonoesters, (13)C NMRS quantified excess glycogen accumulation and NMRI demonstrated progressive fat replacement that paralleled muscle weakness. Multi-parametric functional NMR, performed at recovery from a single bout of aerobic exercise, simultaneously assessed oxidative phosphorylation from (31)P NMRS, muscle perfusion and BOLD, a marker of blood oxygenation, from arterial spin labeled NMRI, and oxygen uptake from deoxymyoglobin proton NMRS. While blocked glycogenolysis caused inadequate substrate supply to the mitochondria, combined measurements suggested that altered perfusion was also responsible for impaired post-exercise phosphocreatine recovery and could contribute to exercise intolerance in GSDIII. These non-invasive investigations provide new indices to quantify the progression of GSDIII.

Для цитирования: Wary Claire, Nadaj-Pakleza Aleksandra, Laforêt Pascal, Claeys Kristl G, Carlier Robert, Monnet Aurélien, Fleury Servanne, Baligand Céline, Eymard Bruno, Labrune Philippe, Carlier Pierre G. Investigating glycogenosis type III patients with multi-parametric functional NMR imaging and spectroscopy.. Neuromuscular disorders : NMD. 2010. DOI: 10.1016/j.nmd.2010.06.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.