MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1583/04-1400mr.1

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2005

Proximal endovascular flow blockage for cerebral protection during carotid artery stenting: results from a prospective multicenter registry.

Reimers Bernhard, Sievert Horst, Schuler Gerhard C, Tübler Thilo, Diederich Klaus, Schmidt Andrej, Rubino Paolo, Mudra Harald, Dudek Dariusz, Coppi Gioacchino, Schofer Joachim, Cremonesi Alberto, Haufe Mathias, Resta Maurizio, Klauss Volker, Benassi Alberto, Di Mario Carlo, Favero Luca, Scheinert Dierk, Salemme Luigi, Biamino Giancarlo

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the feasibility of cerebral protection during carotid artery stenting (CAS) using the Mo.Ma device, which prevents cerebral embolization by proximal endovascular blockage of blood flow in the internal and external carotid arteries.

METHODS

In 14 European centers, 157 patients (121 men; mean age 68.0+/-8.3 years) were enrolled in a prospective registry between March 2002 and March 2003. Eligible patients had a symptomatic (>50%) or asymptomatic (>70%) stenosis of the internal carotid artery suitable for carotid stenting. Protected carotid stenting was performed with the Mo.Ma system, which occludes both the common and external carotid arteries via 2 independently inflatable compliant low-pressure balloons before any device is advanced across the lesion. Blood is aspirated through the catheter intermittently or at the end of the procedure.

RESULTS

The device was successfully positioned and stents were implanted in all cases. Diameter stenosis was reduced from 84.1%+/-7.8% to 6.7%+/-5.1%. The mean duration of flow blockage was 7.6+/-5.9 minutes. In 12 (7.6%) patients, transient intolerance to flow blockade was observed, but the procedures were completed successfully. In 124 (79.6%) cases, there was macroscopic evidence of debris after filtering the aspirated blood. In-hospital complications included 4 (2.5%) minor strokes, 8 (5.1%) transient ischemic attacks, no deaths, and no major strokes, resulting in a 2.5% death/stroke rate at discharge. At 30-day follow-up, there was 1 cardiac death, 1 major stroke, and 3 minor strokes, for an overall 5.7% 30-day death/stroke rate and a 30-day major stroke and death rate of 1.3%.

CONCLUSIONS

Cerebral protection with proximal endovascular blood flow blockage during CAS is feasible, with a high procedural success rate.

Для цитирования: Reimers Bernhard, Sievert Horst, Schuler Gerhard C, Tübler Thilo, Diederich Klaus, Schmidt Andrej, Rubino Paolo, Mudra Harald, Dudek Dariusz, Coppi Gioacchino, Schofer Joachim, Cremonesi Alberto, Haufe Mathias, Resta Maurizio, Klauss Volker, Benassi Alberto, Di Mario Carlo, Favero Luca, Scheinert Dierk, Salemme Luigi, Biamino Giancarlo. Proximal endovascular flow blockage for cerebral protection during carotid artery stenting: results from a prospective multicenter registry.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2005. DOI: 10.1583/04-1400mr.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.