Use of MR signal intensity variations to highlight structures at risk along brain biopsy trajectories.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zanello Marc, Debacker Clément, Moiraghi Alessandro, Peeters Sophie, Roux Alexandre, Deboeuf Louise, Parraga Eduardo, Dezamis Edouard, Chrétien Fabrice, Oppenheim Catherine, Pallud Johan

Аннотация

OBJECTIVE: Postoperative intracerebral hemorrhages are significant complications following brain stereotactic biopsy. They can derive from anatomical structure (sulci, vessels) damage that is missed during stereotactic trajectory planning. In this study, the authors investigated the ability to detect contact between structures at risk and stereotactic trajectories using signal analysis from MRI obtained during clinical practice, with the aim to propose a visual tool to highlight areas with anatomical structures at risk of damage along the biopsy trajectory.

METHODS: The authors retrospectively analyzed actual stereotactic trajectories using intraoperative imaging (intraoperative 2D radiographs in the exploratory data set and intraoperative 3D scans in the confirmatory data set). The MR signal variation along each biopsy trajectory was matched with the patient's anatomy.

RESULTS: In the exploratory data set (n = 154 patients), 32 contacts between the actual biopsy trajectory and an anatomical structure at risk were identified along 28 (18.2%) biopsy trajectories, corresponding to 8 preventable intracerebral hemorrhages. Variations of the mean derivative of the MR signal intensity were significantly different between trajectories with and without contact (the pathological threshold of the mean derivative of the MR signal intensity was defined as ± 0.030 arbitrary units; p < 0.0001), with a sensitivity of 89.3% and specificity of 74.6% to detect a contact. In the confirmatory data set (n = 73 patients), the sensitivity and specificity of the 0.030 threshold to detect a contact between the actual stereotactic trajectory and an anatomical structure at risk were 81.3% and 68.4%, respectively.

CONCLUSIONS: Variations of the mean derivative of the MR signal intensity can be converted into a green/red color code along the planned biopsy trajectory to highlight anatomical structures at risk, which can help neurosurgeons during the surgical planning of stereotactic procedures.