MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archsurg.1995.01430020037004

Медицинская библиотека · Archives of surgery (Chicago, Ill. : 1960) · 1995

Comparison of blood flow and myoelectric measurements in two chronic models of mesenteric ligation.

Brolin R E, Orland P J, Bibbo C, Reddell M T, Fedorciw B, Gazi G, Semmlow J L

Сравнительное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine whether the predictive accuracy of intestinal motility and blood flow measurements is altered by the magnitude of ischemic damage.

DESIGN

Inception cohort study (dogs). Motility was measured using a probe that quantifies both the electromyographic (EMG) measurements and the magnitude of evoked contractile response (ECR). Intestinal blood flow was assessed using Doppler ultrasonography in the marginal artery and perfusion fluorometry, which quantifies fluorescein in the bowel wall in dye fluorescence units.

SETTING

Vivarium animal research facilities at a medical school.

INTERVENTIONS: The blood supply of a 40-cm length of ileum was ligated in 102 dogs: 52 in which the marginal artery was ligated at two points 8 cm apart (severe model), and 50 in which the marginal artery was ligated only once (moderate model). Twenty-four hours after ligation, the motility and blood flow parameters were measured in normal bowel and at 2-cm intervals within the 40-cm ischemic segment. Resection and anastomosis of ischemic bowel was then performed using either EMG, ECR, or fluorometry to determine the site of resection.

OUTCOME MEASURE: Anastomotic leak from progressive ischemia.

RESULTS

There were 26 fatal anastomotic leaks, all due to necrosis at the anastomosis. Perfusion fluorometry and ECR measurements did not correlate with survival in either model. An audible Doppler pulse in the marginal artery correlated with survival in the moderate (P < or = .02) but not the severe model (P = .59). The EMG measurements were significantly greater in survivors vs nonsurvivors in both models.

CONCLUSIONS

The EMG measurements may be useful in bowel viability assessment. Correlation of Doppler ultrasonographic findings with survival in the moderate model suggests that blood flow measurements may be more reliable in predicting viability in less ischemic bowel.

Для цитирования: Brolin R E, Orland P J, Bibbo C, Reddell M T, Fedorciw B, Gazi G, Semmlow J L. Comparison of blood flow and myoelectric measurements in two chronic models of mesenteric ligation.. Archives of surgery (Chicago, Ill. : 1960). 1995. DOI: 10.1001/archsurg.1995.01430020037004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.