MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/alr.21475

Медицинская библиотека · International forum of allergy & rhinology · 2015

Magnetic resonance cisternogram with intrathecal gadolinium with delayed imaging for difficult to diagnose cerebrospinal fluid leaks of anterior skull base.

DelGaudio John M, Baugnon Kristen L, Wise Sarah K, Patel Zara M, Aiken Ashley H, Hudgins Patricia A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Workup of cerebrospinal fluid (CSF) leaks can be challenging. Patients with intermittent or infrequent clear rhinorrhea that cannot be collected, those with questionable or multiple skull-base (SB) defects on imaging, and those with previous SB surgery can present diagnostic dilemmas. In this patient population, radiologic studies that allow repeat imaging over hours to days can increase the diagnostic yield. We report our experience with magnetic resonance cisternogram with intrathecal gadolinium (MRCgGd) in this patient population.

METHODS

This study was a retrospective review of patients who underwent MRCgGd for workup of suspected CSF leaks at a tertiary care academic center.

RESULTS

Over the past 3 years, 11 patients (10 females; mean age 50 years) underwent MRCgGd. Seven patients had suspected spontaneous CSF leaks from idiopathic intracranial hypertension and 2 had postsurgical defects. All patients had previous imaging that was indeterminate in localizing the site of the leak. Only 3 patients had positive beta-2 transferrin studies, all with multiple potential leak sites. MRCgGd confirmed the absence of leaks at 4 previously repaired SB defects, identified spinal canal leaks but no SB leaks in 2 patients (1 of whom had a nonleaking SB defect), and identified 5 patients with one or more SB leaks. Repeat imaging, from 30 minutes to 20 hours, was beneficial in identifying 4 leaks not confirmed in the immediate imaging, and ruling out leaks in 5 cases, therefore guiding further treatment. No complications occurred.

CONCLUSION

MRCgGd is a useful diagnostic test in the workup of patients with difficult CSF leaks, with delayed imaging providing valuable diagnostic information.

Для цитирования: DelGaudio John M, Baugnon Kristen L, Wise Sarah K, Patel Zara M, Aiken Ashley H, Hudgins Patricia A. Magnetic resonance cisternogram with intrathecal gadolinium with delayed imaging for difficult to diagnose cerebrospinal fluid leaks of anterior skull base.. International forum of allergy & rhinology. 2015. DOI: 10.1002/alr.21475.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.