m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2018

Long-term outcomes after re-entry device use for recanalization of common iliac artery chronic total occlusions.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kokkinidis Damianos G, Alvandi Bejan, Cotter Ryan, Hossain Prio, Foley T Raymond, Singh Gagan D, Waldo Stephen W, Laird John R, Armstrong Ehrin J

Аннотация

OBJECTIVE: To examine the impact of re-entry device (RED) use on 1- and 5-year outcomes after endovascular treatment of common iliac artery (CIA) chronic total Occlusions (CTOs).

BACKGROUND: There are not enough data regarding the long-term safety and efficacy of RED.

METHODS: We performed a two-center retrospective study of 115 patients (140 lesions) undergoing CIA CTO endovascular intervention between 2006 and 2016. Baseline characteristics and long-term outcomes were described. A Cox proportional hazard model was developed to determine if REDs were associated with target lesion revascularization (TLR) or major adverse limb events (MALE) after 1 and 5 years.

RESULTS: Among 140 lesions, 43 (31%) required use of a RED. The mean age was 63.9 years and the majority (n = 80) of patients were male. An antegrade crossing approach and treatment of restenotic lesions were less common in the RED group (10% vs. 29%, P < .05 and 0% vs. 21%, P < .05, respectively). There were no significant differences in Rutherford class, pre-procedure ABI, or patient presentation. The procedural complication rates were similar between the two groups. The 1- and 5-year TLR rates for lesions treated with re-entry device vs. standard approaches were 11% vs. 9%; P = 0.8 and 29% vs. 29%; P = 0.9 respectively. The 1 and 5-year MALE rates for lesions treated with re-entry device were 5% vs. 6%; P = 0.8 and 11% vs. 11%; P = 0.9 respectively.

CONCLUSIONS: This retrospective analysis found that recanalization of CIA occlusions using a RED is safe and is associated with long-term clinical outcomes similar to that of standard crossing techniques.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты