DOI 10.1093/ageing/aft112

Медицинская библиотека · Age and ageing · 2013

The prevalence and pathological correlates of orthostatic hypotension and its subtypes when measured using beat-to-beat technology in a sample of older adults living in the community.

Cooke John, Carew Sheila, Quinn Colin, O'Connor Margaret, Curtin John, O'Connor Caroline, Saunders Jean, Humphreys Eileen, Deburca Stiofan, Clinch David, Lyons Declan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

beat-to-beat technology is increasingly used for investigating orthostatic intolerance (OI) but the prevalence of orthostatic hypotension (OH) diagnosed with this technology is unclear.

OBJECTIVES

(i) to use beat-to-beat technology to define the prevalence of OH, (ii) to investigate the pathological correlates of OH, (iii) to report the diversity of postural BP responses.

METHODS

cross-sectional study of adults ≥ 65 years. BP responses to a 3-min head-up tilt were analysed.

RESULTS

of 326 participants, 203(62.3%) were females. The median (IQR) age was 73 (70-78). One hundred and ninety-one (58.6%) met standard (20 mmHg systolic/10 mmHg diastolic) criteria for OH. The prevalence was higher in females (60.1% F versus 56.1% M); 47% were arteriolar subtype, 33% were venular, 9% were mixed and 11.0% could not be classified. Morphological analysis identified 102 subjects with 'small drop, overshoot', 131 with 'medium drop, slow recovery' and 31 with 'large drop, nonrecovery'. Those with OH had a lower BMI (P = 0.02), a higher resting heart rate (P = 0.005), were more likely to take a psychotropic (P = 0.02), have vertigo (P = 0.004) and report OI (P = 0.02). The 95th centile for the duration of systolic BP (SYSBP) decay >20 mmHg was 175 s and the slope of systolic BP decay was 4.75 mmHg/s. The 5th centile for percentage recovery of SYSBP was 81.4%.

CONCLUSION

(i) beat-to-beat methods identify a higher prevalence of OH than sphygmomanometry, (ii) the pathological correlates of OH diagnosed in this manner are similar to those described for sphygmomanometry, (iii) there is a diverse pattern of orthostatic BP decay that could be used in future research to predict adverse outcomes in OH.

Для цитирования: Cooke John, Carew Sheila, Quinn Colin, O'Connor Margaret, Curtin John, O'Connor Caroline, Saunders Jean, Humphreys Eileen, Deburca Stiofan, Clinch David, Lyons Declan. The prevalence and pathological correlates of orthostatic hypotension and its subtypes when measured using beat-to-beat technology in a sample of older adults living in the community.. Age and ageing. 2013. DOI: 10.1093/ageing/aft112.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.