m+Medelevator.RU
← Поиск публикаций
Journal of the American College of Cardiology · 2001

Circulatory response to fluid overload removal by extracorporeal ultrafiltration in refractory congestive heart failure.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Marenzi G, Lauri G, Grazi M, Assanelli E, Campodonico J, Agostoni P

Аннотация

OBJECTIVES: The goal of this study was to investigate the hemodynamic and circulatory adjustments to extracorporeal ultrafiltration (UF) in refractory congestive heart failure (rCHF).

BACKGROUND: In rCHF, UF allows clinical improvement and restores diuretic efficacy. However, in the course of a UF session, patients are exposed to rapid variations of body fluid composition so that, as fluid is withdrawn from the intravascular compartment, hypotension or even shock could occur.

METHODS: In 24 patients with rCHF undergoing UF, we measured, after every liter of plasma water removed, hemodynamics, blood gas analysis (in both systemic and pulmonary arteries), plasma volume changes (PV) and plasma refilling rate (PRR). The PV and PRR were calculated by considering hematocrit and ultrafiltrate volume.

RESULTS: In all patients, UF was performed safely, without side effects or hemodynamic instability (ultrafiltrate = 4,880 +/- 896 ml). Mean right atrial, pulmonary artery and wedge pressures progressively reduced during the procedure. Cardiac output increased at the end of the procedure and, to a greater extent, 24 h later, in relation to the increase of stroke volume. Heart rate and systemic vascular resistance did not increase, and other peripheral biochemical parameters did not worsen during UF. Intravascular volume remained stable throughout the entire duration of the procedure, indicating that a proportional volume of fluid was refilled from the congested parenchyma.

CONCLUSIONS: In patients with rCHF, subtraction of plasma water by UF is associated with hemodynamic improvement. Fluid refilling from the overhydrated interstitium is the major compensatory mechanism for intravascular fluid removal, and hypotension does not occur when plasma refilling rate is adequate to prevent hypovolemia.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты