m+Medelevator.RU
← Поиск публикаций
The Journal of nutrition · 2009

Newborn adiposity measured by plethysmography is not predicted by late gestation two-dimensional ultrasound measures of fetal growth.

СтатьяПоддержка NIH: внешняя программаВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Moyer-Mileur Laurie J, Slater Hillarie, Thomson J Anne, Mihalopoulos Nicole, Byrne Jan, Varner Michael W

Аннотация

Noninvasive measures of fetal and neonatal body composition may provide early identification of children at risk for obesity. Air displacement plethysmography provides a safe, precise measure of adiposity and has recently been validated in infants. Therefore, we explored relationships between term newborn percent body fat (%BF) measured by air displacement plethysmography to 2-dimensional ultrasound (2-D US) biometric measures of fetal growth and maternal and umbilical cord endocrine activity. A total of 47 mother/infant pairs were studied. Fetal biometrics by 2-D US and maternal blood samples were collected during late gestation (35 wk postmenstrual age); infants were measured within 72 h of birth. Fetal biometrics included biparietal diameter, femur length, head circumference, abdominal circumference (AC), and estimated fetal weight (EFW). Serum insulin, insulin-like growth factor (IGF) 1, IGF binding protein-3, and leptin concentrations were measured in umbilical cord and maternal serum. The mean %BF determined by plethysmography was 10.9 +/- 4.8%. EFW and fetal AC had the largest correlations with newborn %BF (R(2) = 0.14 and 0.10, respectively; P < 0.05); however, stepwise linear regression modeling did not identify any fetal biometric parameters as a significant predictor of newborn %BF. Newborn mid-thigh circumference (MTC; cm) and ponderal index (PI; weight, kg/length, cm(3)) explained 21.8 and 14.4% of the variability in %BF, respectively, and gave the best stepwise linear regression model (%BF = 0.446 MTC + 0.347 PI -29.692; P < 0.001). We conclude that fetal growth biometrics determined by 2-D US do not provide a reliable assessment of %BF in term infants.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты